Description
The product comes with Part Numbers 779967-01, 779967-02, and 779967-03, providing a range of options to choose from. It boasts a Memory Options capacity of 8 to 512 MB per channel, which translates to 4 to 256 million 14-bit samples per channel, ensuring ample storage for high-density data acquisition.
In terms of Triggered Waveforms Acquisition, it is capable of capturing more than 1 million waveforms without the need for software intervention in multiple-record mode. This feature is complemented by a Timestamp Resolution of 100 ps in both single-shot and various record acquisition modes, providing precise time measurements for each waveform captured.
The device is highly compatible with various drivers, as indicated by the Driver Compatibility specification. It supports NI-SCOPE and is compatible with NI LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Studio 6.0 and .NET, offering flexibility in software environments for development and analysis.
With a Sampling Rate of 100 Msamples/sec in real-time and 2.0 Gsamples/sec in random interleaved mode, the product ensures high-speed data capture. This is further enhanced by a Bandwidth of 100 MHz, allowing for a wide range of signal frequencies to be accurately represented.
The Input Impedance can be set to either 50 ohm or 1 Mohm, providing programmable selectivity to match the impedance of the signal source, thereby minimizing signal reflections and distortions. Furthermore, the Input Range of 200mV to 20V offers versatility in accommodating signals of various amplitudes.
Signal fidelity is a key aspect, as evidenced by an SFDR (Spurious-Free Dynamic Range) of 75 dBc and a SINAD (Signal-to-Noise and Distortion ratio) of 62 dB, ensuring that the signal integrity is maintained during acquisition and analysis.
With regard to memory allocation, each channel can be equipped with 8, 32, or 256 Mbytes of Memory per Channel, allowing users to select the memory size that best suits
| Specification | Details |
|---|---|
| Part Numbers | 779967-01, 779967-02, 779967-03 |
| Memory Options | 8 to 512 MB per channel (4 to 256 million 14-bit samples per channel) |
| Triggered Waveforms Acquisition | More than 1 million without software intervention in multiple-record mode |
| Timestamp Resolution | 100 ps in both single-shot and various record acquisition modes |
| Driver Compatibility | NI-SCOPE, compatible with NI LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Studio 6.0 and .NET |
| Sampling Rate | 100 Msamples/sec real-time, 2.0 Gsamples/sec random interleaved |
| Bandwidth | 100 MHz |
| Input Impedance | 50 ohm or 1 Mohm, programmable selectable |
| Input Range | 200mV to 20V |
| SFDR | 75 dBc |
| SINAD | 62 dB |
| Memory per Channel | 8, 32, or 256 Mbytes |
| Triggering Types | Edge, window, hysteresis, video, and logic triggering with 100 ps timestamping | Question 1: What is the maximum memory per channel for PXIe-5122?