Description
The product features a variety of Part Numbers, including 779967-01, 779967-02, and 779967-03, offering flexibility for different configurations and requirements.
It offers a wide range of Memory Options, from 8 to 512 MB per channel. This translates to 4 to 256 million 14-bit samples per channel, providing ample storage for complex data acquisition tasks.
With its Triggered Waveforms Acquisition capability, it can capture more than 1 million waveforms without software intervention in multiple-record acquisition mode, making it highly efficient for automated testing environments.
The Timestamp Resolution is exceptionally precise at 100 ps in both single-shot and various record acquisition modes, ensuring accurate time measurements are captured for each waveform.
Its Driver Compatibility is extensive, supporting the NI-SCOPE driver. It is compatible with NI LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Studio 6.0 and .NET, offering versatility in software environments.
The Digitizer Format is a 100-MHz, 100 Msamples/sec, 14-bit digitizer in PXI format. This high-resolution digitizer ensures detailed and accurate data capture.
It features Two channels, which are simultaneously sampled at 14-bit resolution, allowing for dual-channel measurements without compromise on data integrity.
Its Sampling Rate is impressive, with 100 Msamples/sec real-time and 2.0 Gsamples/sec random interleaved sampling, facilitating high-speed data acquisition.
The Bandwidth of 100 MHz supports a wide range of frequencies, suitable for capturing a variety of signals in different applications.
Input Impedance can be switched between 50 ohm or 1 Mohm, software selectable, providing flexibility in adapting to different signal sources.
The Input Range is versatile, from 200mV to 20V, accommodating a broad spectrum of signal amplitudes.
SFDR (Spurious-Free Dynamic Range) is rated at 75 dBc, indicating
| Feature | Description |
|---|---|
| Part Numbers | 779967-01, 779967-02, 779967-03 |
| Memory Options | 8 to 512 MB per channel (4 to 256 million 14-bit samples per channel) |
| Triggered Waveforms Acquisition | More than 1 million without software intervention in multiple-record acquisition mode |
| Timestamp Resolution | 100 ps in both single-shot and various record acquisition modes |
| Driver Compatibility | NI-SCOPE driver, compatible with NI LabVIEW, LabWindows/CVI, and Measurement Studio for Visual Studio 6.0 and .NET |
| Digitizer Format | 100-MHz, 100 Msamples/sec, 14-bit digitizer in PXI format |
| Channels | Two channels, simultaneously sampled at 14-bit resolution |
| Sampling Rate | 100 Msamples/sec real-time and 2.0 Gsamples/sec random interleaved sampling |
| Bandwidth | 100 MHz |
| Input Impedance | 50 ohm or 1 Mohm, software selectable |
| Input Range | 200mV to 20V |
| SFDR | 75 dBc |
| SINAD | 62 dB |