img

195945G-02L

Featuring part numbers 779967-01 to 03, this device offers 8-512 MB/channel memory, 100 Msamples/sec, 14-bit resolution, with 100 MHz bandwidth.

In Stock | Ships Today

img

    Description

    The product comes with Part Numbers 779967-01, 779967-02, and 779967-03, offering a range of options to suit various requirements. It features extensive Memory Options ranging from 8 to 512 MB per channel, equivalent to 4 to 256 million 14-bit samples per channel, catering to diverse data storage needs.

    With a Digitizer/Sampling Rate of 100 Msamples/sec in real-time and up to 2.0 Gsamples/sec in random interleaved sampling, it ensures high-speed data acquisition and processing. The Resolution is specified at 14-bit, providing high precision in measurements.

    The device boasts a Bandwidth of 100 MHz, facilitating the capture of a wide range of frequencies. The Input Impedance can be easily switched between 50 ohm or 1 Mohm through software, allowing flexibility in connection to different signal sources.

    Its Input Range spans from 200mV to 20V, accommodating a variety of signal amplitudes. The product demonstrates excellent signal integrity with an SFDR (Spurious-Free Dynamic Range) of 75 dBc and a SINAD (Signal-to-Noise and Distortion) of 62 dB.

    For each channel, the Memory per Channel can be configured as 8, 32, or 256 Mbytes, providing versatility in data storage capacity. It supports multiple Triggering modes including edge, window, hysteresis, video, and advanced with 100 ps timestamping, offering precise control over data capture timing.

    The device is compatible with Windows 2000/XP operating systems, ensuring easy integration into existing setups. It also Includes NI-SCOPE driver software, simplifying the installation and setup process, enabling users to start their projects swiftly and efficiently.

    Specification Detail
    Part Numbers 779967-01, 779967-02, 779967-03
    Memory Options 8 to 512 MB per channel (4 to 256 million 14-bit samples per channel)
    Digitizer/Sampling Rate 100 Msamples/sec real-time, 2.0 Gsamples/sec random interleaved sampling
    Resolution 14-bit
    Bandwidth 100 MHz
    Input Impedance 50 ohm or 1 Mohm, software selectable
    Input Range 200mV to 20V
    SFDR 75 dBc
    SINAD 62 dB
    Memory per Channel 8, 32, or 256 Mbytes
    Triggering Edge, window, hysteresis, video, and advanced with 100 ps timestamping
    Compatible Operating Systems Windows 2000/XP
    Driver Software Includes NI-SCOPE driver software

    Question 1: What is the sampling rate of the PXIe-5122?
    Answer 1: 100 Msamples/sec, and up to 2.0 Gsamples/sec in random sampling.

    Question 2: How versatile is the memory per channel for the PXIe-5122?
    Answer 2: Options from 8 to 512 MB, equaling 4 to 256 million samples.

    Question 3: What resolution does the PXIe-5122 offer?
    Answer 3: 14-bit, providing high precision measurements.

    Question 4: Can the input impedance on the PXIe-5122 be changed?
    Answer 4: Yes, switchable between 50 ohm or 1 Mohm via software.

    Question 5: What operating systems is the PXIe-5122 compatible with?
    Answer 5: Windows 2000/XP, facilitating easy integration.