Description
The Part Number 195945H-03L refers to a high-performance PXI Oscilloscope/Digitizer, specifically the model PXIe-5122. This device is designed to provide advanced signal capturing capabilities and is suitable for a wide range of applications.
One of the key features of the PXIe-5122 is its Memory Options, which range from 8 to 512 MB per channel. This translates to 4 to 256 million 14-bit samples per channel, allowing for extensive data collection and analysis. Furthermore, it boasts an impressive ability to acquire more than 1 million triggered waveforms without requiring software intervention, making it an efficient tool for capturing transient events.
The device also features a Timestamp Resolution of 100 picoseconds, ensuring precise timing analysis of captured waveforms. This precision is complemented by its streaming capability, which allows data to be transferred from onboard memory to disk seamlessly, facilitating long-term data logging and analysis.
For software integration, the PXIe-5122 uses NI-SCOPE driver software, which simplifies the development of custom applications and integration with existing systems. This model supports a sampling rate of 100 Msamples/sec in real-time and 2.0 Gsamples/sec in random interleaved mode, offering flexibility in capturing high-speed signals. Additionally, its 100 MHz bandwidth is suitable for a wide range of signal frequencies.
The device provides the option to select between 50 ohm or 1 Mohm input impedance, which is software selectable, offering versatility in connecting different types of signal sources. Its input range spans from 200mV to 20V, accommodating various signal amplitudes. The PXIe-5122 also delivers excellent signal fidelity, with a Spurious-Free Dynamic Range (SFDR) of 75 dBc and a Signal-to-Noise and Distortion (SINAD) ratio of 62
| Feature | Specification |
|---|---|
| Part Number | 195945H-03L |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXIe-5122 |
| Memory Options | 8 to 512 MB per channel (4 to 256 million 14-bit samples per channel) |
| Triggered Waveforms Acquisition | More than 1 million without software intervention |
| Timestamp Resolution | 100 ps |
| Streaming Capability | Yes, from onboard memory to disk |
| Driver Software | NI-SCOPE |
| Sampling Rate | 100 Msamples/sec real-time, 2.0 Gsamples/sec random interleaved |
| Bandwidth | 100 MHz |
| Input Impedance | 50 ohm or 1 Mohm, software selectable |
| Input Range | 200mV to 20V |
| SFDR | 75 dBc |
| SINAD | 62 dB |
| Memory per Channel | 8, 32, or 256 Mbytes |