Description
The National Instruments PXIe-5111 is a high-performance PXI Oscilloscope/Digitizer designed to meet a wide range of testing and measurement needs. Manufactured by National Instruments, this model is an integral part of advanced measurement systems, providing exceptional capabilities for engineers and scientists.
This model comes with various part numbers, including 785769-01, 785769-11, 785770-01, and 785770-11, allowing users to choose the specific configuration that best fits their requirements. The PXIe-5111 is known for its compatibility with NI-SCOPE driver software, which facilitates seamless integration and operation within measurement systems. Furthermore, it supports a broad range of application software such as LabVIEW, LabWindows, and Measurement Studio, among others, ensuring versatility across different platforms and programming environments.
The device connects via the PXIe bus connector, ensuring high-speed data transfer and synchronization with other PXI modules. With two voltage input channels, it can handle complex measurements and analyses. The PXIe-5111 boasts a maximum sampling rate of 3 GS/s and a maximum bandwidth of 350 MHz, providing high-resolution and accurate measurements. Its 8-bit resolution ensures that data is captured with high fidelity, capturing the nuances of the signal being measured.
Users can select between 64 MB and 512 MB of onboard memory sizes, accommodating a wide range of data storage needs. The input impedance can be set to either 50 Ohm or 1 MOhm, offering flexibility for different testing scenarios. Additionally, the input voltage range is quite generous, extending from -20 V to 20 V. The device supports both DC and AC coupling modes, providing versatility in signal analysis.
The PXIe-5111 is equipped with multiple triggering modes, allowing for precise control over measurement timing and synchronization. Advanced features of this model include PXI synchronization, data throughput facilities, and programmable settings (such as filtering, coupling, voltage range, and input impedance) to tailor the device’s operation to specific needs. The <
Specification | Details |
---|---|
Manufacturer | National Instruments |
Model | PXIe-5111 |
Part Numbers | 785769-01, 785769-11, 785770-01, 785770-11 |
Category | PXI Oscilloscopes/Digitizers |
Onboard Memory Sizes | 64 MB, 512 MB |
Driver Software | NI-SCOPE |
Application Software Compatibility | LabVIEW, LabWindows, Measurement Studio, etc. |
Bus Connector | PXIe |
Voltage Input Channels | 2 |
Maximum Sampling Rate | 3 GS/s |
Maximum Bandwidth | 350 MHz |
Resolution | 8 bits |
Input Impedance | 50 Ohm or 1 MOhm |
Input Voltage Range | -20 V to 20 V |
Coupling Modes | DC, AC |
Triggering Modes | Multiple |
Advanced Features | PXI synchronization, Data throughput facilities, Programmable settings (filtering, coupling, voltage range, input impedance), CableSense technology (specific part numbers) |
Form Factor | Gen 1 x4 module |
Question 1: What is the max bandwidth of the PXIe-5111?
Answer 1: 350 MHz
Question 2: What sampling rate does the PXIe-5111 support?
Answer 2: 3 GS/s
Question 3: How many input channels does the PXIe-5111 have?
Answer 3: Two voltage input channels
Question 4: What is the max onboard memory for the PXIe-5111?
Answer 4: 512 MB
Question 5: Can the PXIe-5111 use LabVIEW software?
Answer 5: Yes, it supports LabVIEW