PCI-6133

The National Instruments PCI-6133 is a multifunction I/O device featuring 8 input channels with 14-bit ADC resolution, a sampling rate of 2.5 MS/s per channel, and various data transfer mechanisms including DMA or interrupt, designed

In Stock | Ships Today

img

    Description

    The National Instruments PCI-6133 Multifunction I/O Device is a versatile data acquisition tool with part numbers 779420-01, 779421-01, and 191215A-03. It features eight input channels and boasts an ADC resolution of 14 bits, providing precise data capture. With a high sampling rate of 2.5 MS/s per channel, it ensures rapid data acquisition for each input.

    The device is designed with DC input coupling and has a substantial input FIFO size, which can handle up to 32 MS of data. To facilitate efficient data handling, it supports both DMA and interrupt-based data transfer mechanisms. Before starting any measurement, it is recommended to allow a warm-up time of 15 minutes.

    In addition to its analog capabilities, the PCI-6133 includes eight digital I/O channels that are compatible with TTL and CMOS logic levels. It also features two counter/timer I/O lines with a 24-bit resolution and a frequency of 20 MHz, which is ideal for precise timing and counting tasks. The device connects to systems through a 68-pin male SCSI II I/O connector.

    The unit is operated using NIDAQmx driver software, which is compatible with various application development environments such as LabVIEW, LabWindows/CVI, and Measurement Studio. Users can verify the device’s functionality using the Measurement & Automation Explorer (MAX) tool. Moreover, the PCI-6133 offers versatile trigger capabilities, including digital, analog, and RTSI options, which allow for flexible system integration and synchronization.

    Question 1: What are the key features and specifications of the National Instruments PCI-6133 Multifunction I/O Device that facilitate precise and rapid data collection and system integration?
    Answer 1: The National Instruments PCI-6133 Multifunction I/O Device supports a maximum sampling rate of 2.5 MS/s per channel and features eight analog input channels.

    Question 2: What are the key features and system requirements for effectively operating the National Instruments PCI-6133 Multifunction I/O Device within a data acquisition setup?
    Answer 2: The National Instruments PCI-6133 Multifunction I/O Device provides a sampling rate of 2.5 MS/s per channel, and it is recommended to be operated using the NIDAQmx driver software.

    Question 3: What is the maximum sampling rate per channel for the National Instruments PCI-6133 Multifunction I/O Device, and what type of input channels does it support?
    Answer 3: The National Instruments PCI-6133 Multifunction I/O Device offers eight analog input channels with a 14-bit ADC resolution and a sampling rate of 2.5 MS/s per channel, eight digital I/O channels compatible with TTL and CMOS logic levels, and two counter/timer I/O lines with 24-bit resolution and a 20 MHz frequency; it is operated using NIDAQmx driver software, which is compatible with development environments like LabVIEW, LabWindows/CVI, and

    Question 4: What sampling rate per channel does the National Instruments PCI-6133 Multifunction I/O Device provide, and what software is recommended for operating this device?
    Answer 4: The key features of the National Instruments PCI-6133 Multifunction I/O Device include eight input channels with a 14-bit ADC resolution, a high sampling rate of 2.5 MS/s per channel, DC input coupling, a 32 MS input FIFO size, support for DMA and interrupt-based data transfers, a warm-up time of 15 minutes, eight digital I/O channels, two 24-bit counter/timer I/O lines with a 20 MHz frequency, and a 68

    Question 5: What are the input and output capabilities of the National Instruments PCI-6133 Multifunction I/O Device, and what software is used to operate it?
    Answer 5: The National Instruments PCI-6133 Multifunction I/O Device features eight input channels with a 14-bit ADC resolution and a high sampling rate of 2.5 MS/s per channel, a DC input coupling, a 32 MS input FIFO size, DMA and interrupt-based data transfer mechanisms, and a warm-up time of 15 minutes, as well as eight digital I/O channels, two counter/timer I/O lines with a 24-bit resolution at 20 MHz frequency, a

    Feature Specification
    Product National Instruments PCI-6133 Multifunction I/O Device
    Part Numbers 779420-01, 779421-01, 191215A-03
    Input Channels 8
    ADC Resolution 14 bits
    Sampling Rate 2.5 MS/s per channel
    Input Coupling DC
    Input FIFO Size Up to 32 MS
    Data Transfer Mechanisms DMA or interrupt
    Warm-Up Time 15 minutes
    Digital I/O Channels 8 (TTL/CMOS compatible)
    Counter/Timer I/O 2 lines, 24-bit resolution, 20 MHz
    I/O Connector 68-pin male SCSI II
    Driver Software NIDAQmx (compatible with LabVIEW, LabWindows/CVI, Measurement Studio)
    Verification Tool Measurement & Automation Explorer (MAX)
    Trigger Capabilities Digital, analog, RTSI