Description
Part Numbers 784181-01, 785114-01 are the unique identifiers for this product, ensuring you have the exact specification you need for your requirements.
Maximum Frequency of 20 MHz allows for high-speed operations and ensures efficient performance across a variety of applications.
Step Response Rise Time is exceptionally fast at 14.8 ns, providing an indication of the system’s high responsiveness to input signal changes.
Arbitrary Waveform Size can range from 2 to 64,000,000 samples, offering tremendous flexibility in waveform generation for complex and varied applications.
User Sample Rate can vary significantly depending on whether the digital filter is enabled or disabled. With the digital filter enabled, the sample rate ranges from 5.6 µS/s to 200 MS/s. With the digital filter disabled, it ranges from 3.125 MS/s to 200 MS/s, providing versatile options for precise data acquisition and signal processing.
Frequency Step Size is incredibly precise at 2.84 µHz, allowing for very fine adjustments to the frequency, enhancing the accuracy of signal generation and analysis.
Waveform Points total 8,192, offering a substantial number of data points for generating detailed and accurate waveforms.
Reference Clock Frequency is stable at 100 MHz (±25 ppm), which ensures that the timing of the waveform generation and processing is highly accurate and reliable.
Sample Clock Rate at a high speed of 800 MHz facilitates rapid data processing, allowing for efficient handling of high-bandwidth signals.
PFI I/O Frequency Range spans from 0 MHz to 25 MHz, providing a wide range for input/output operations, suitable for a variety of digital applications.
Maximum Input Voltage is rated at +5 V, ensuring compatibility with a broad range of external devices and signals without risking damage to the system.
Operating Shock tolerance is robust at 30 g peak, half-sine, 11 ms pulse, indicating the product’s ability to withstand significant physical shocks during operation without suffering damage.
| Specification | Details |
|---|---|
| Part Numbers | 784181-01, 785114-01 |
| Maximum Frequency | 20 MHz |
| Step Response Rise Time | 14.8 ns |
| Arbitrary Waveform Size | 2 to 64,000,000 samples |
| User Sample Rate (Digital Filter Enabled) | 5.6 µS/s to 200 MS/s |
| User Sample Rate (Digital Filter Disabled) | 3.125 MS/s to 200 MS/s |
| Frequency Step Size | 2.84 µHz |
| Waveform Points | 8,192 |
| Reference Clock Frequency | 100 MHz (±25 ppm) |
| Sample Clock Rate | 800 MHz |
| PFI I/O Frequency Range | 0 MHz to 25 MHz |
| Maximum Input Voltage | +5 V |
| Operating Shock | 30 g peak, half-sine, 11 ms pulse |
| Operating Random Vibration | 5 Hz to 500 Hz, 0.3 grms |
| Non-Operating Random Vibration | Question 1: What are the part numbers for PXIe-5413? Answer 1: 784181-01 and 785114-01 Question 2: What is the maximum frequency of the PXIe-5413? Question 3: How fast is the step response rise time? Question 4: What’s the sample rate with the digital filter enabled? Question 5: What is the sample clock rate for PXIe-5413? |