Description
The PXIe-5413 is a highly specialized equipment designed to meet various technical requirements. Its part numbers are 784181-01 and 785114-01, indicating different versions or configurations available for specific applications. This device supports a frequency range of up to 20 MHz, making it suitable for a wide range of signal generation tasks.
The step response rise time is exceptionally quick at 14.8 ns, ensuring that signals are generated with minimal delay. It offers an extensive arbitrary waveform size range from 2 samples to 64,000,000 samples, providing users with tremendous flexibility in waveform generation. The user sample rate can be adjusted from 5.6 µS/s to 200 MS/s when the digital filter is enabled, and from 3.125 MS/s to 200 MS/s when the digital filter is disabled, accommodating a wide range of sampling needs.
The device boasts a precise frequency step size of 2.84 µHz, allowing for finely tuned frequency adjustments. With 8,192 waveform points, users have ample capacity for creating detailed waveforms. The reference clock frequency is set at 100 MHz (<±25 ppm), ensuring accurate timing, while the sample clock rate reaches up to 800 MHz, facilitating high-speed operations.
For interfacing, the PFI I/O frequency range spans from 0 MHz to 25 MHz, accommodating a variety of external devices and signals. Its maximum input voltage is rated at +5 V, indicating the level of signal amplitude it can safely accept. The device is designed to withstand operating shock conditions up to 30 g peak, with a half-sine, 11 ms pulse, demonstrating its robustness in harsh environments.
In terms of vibration tolerance, it operates reliably
| Specification | Detail |
|---|---|
| Model | PXIe-5413 |
| Part Numbers | 784181-01, 785114-01 |
| Frequency Range | Up to 20 MHz |
| Step Response Rise Time | 14.8 ns |
| Arbitrary Waveform Size | 2 samples to 64,000,000 samples |
| User Sample Rate (Digital Filter Enabled) | 5.6 µS/s to 200 MS/s |
| User Sample Rate (Digital Filter Disabled) | 3.125 MS/s to 200 MS/s |
| Frequency Step Size | 2.84 µHz |
| Waveform Points | 8,192 |
| Reference Clock Frequency | 100 MHz (<±25 ppm) |
| Sample Clock Rate | 800 MHz |
| PFI I/O Frequency Range | 0 MHz to 25 MHz |
| Maximum Input Voltage | +5 V |
| Operating Shock | 30 g peak, half-sine, 11 ms pulse |
| Random Vibration (Operating) | 5 Hz to 500 Hz, 0.3 grms |
| Random Vibration (Non-Operating) | 5 Hz to 500 Hz, 2.4 grms |
Question 1: What is the frequency range of the PXIe-5413?
Answer 1: Up to 20 MHz
Question 2: What is the step response rise time of the PXIe-5413?
Answer 2: 14.8 ns
Question 3: How many samples can the PXIe-5413 support?
Answer 3: Up to 64M samples
Question 4: What is the max sample clock rate of the PXIe-5413?
Answer 4: Up to 800 MHz
Question 5: What is the PFI I/O frequency range of the PXIe-5413?
Answer 5: 0 MHz to 25 MHz