200426A-01

The PXIe-5413 is a 20MHz, 2-channel, 16-bit Arbitrary Waveform Generator with a sample rate up to 200 MS/s and waveform size up to 64M samples.

In Stock | Ships Today

img

    Description

    The PXIe-5413 is a PXI Arbitrary Waveform Generator that falls under the category of PXI Arbitrary Waveform Generators. This system element is designed for ECUTS, offering a maximum frequency of 20 MHz and a step response rise time of 14.8 ns. It supports an arbitrary waveform size ranging from 2 samples to 64,000,000 samples, catering to a wide variety of waveform generation needs.

    The user sample rate with the digital filter enabled ranges from 5.6 µS/s to 200 MS/s, while with the digital filter disabled, it ranges from 3.125 MS/s to 200 MS/s. This flexibility allows for precise control over waveform generation, ensuring compatibility with a broad spectrum of applications. The frequency step size of 2.84 µHz allows for fine-tuning of the output signal.

    With 8,192 waveform points, this waveform generator provides ample resolution for generating complex waveforms. The reference clock frequency is 100 MHz (<±25 ppm), and it boasts a sample clock rate of 800 MHz, ensuring high precision and accuracy in waveform generation.

    The part number for this PXI Arbitrary Waveform Generator is 200426A-01, with alternative part numbers being 784181-01 and 785114-01. This information is crucial for identifying the exact model and specifications when ordering or requesting support.

    Specification Details
    Part Number 200426A-01
    Alternative Part Numbers 784181-01, 785114-01
    Category PXI Arbitrary Waveform Generators
    Model PXIe-5413
    Description System Element, ECUTS, PXIe-5413, 20MHz, 2Ch, 16B, 160T, AWG
    Maximum Frequency 20 MHz
    Step Response Rise Time 14.8 ns
    Arbitrary Waveform Size 2 samples to 64,000,000 samples
    User Sample Rate (Digital Filter Enabled) 5.6 µS/s to 200 MS/s
    User Sample Rate (Digital Filter Disabled) 3.125 MS/s to 200 MS/s
    Frequency Step Size 2.84 µHz
    Waveform Points 8,192
    Reference Clock Frequency 100 MHz (<±25 ppm)
    Sample Clock Rate 800 MHz
    PFI

    Question 1: What is the max frequency of PXIe-5413?
    Answer 1: 20 MHz

    Question 2: What sample rate does the PXIe-5413 offer?
    Answer 2: Up to 200 MS/s

    Question 3: How large can the waveform size be on PXIe-5413?
    Answer 3: Up to 64M samples

    Question 4: What’s the reference clock frequency of PXIe-5413?
    Answer 4: 100 MHz (<±25 ppm)

    Question 5: What part numbers are associated with PXIe-5413?
    Answer 5: 200426A-01, 784181-01, 785114-01