Description
The 785114-01 is a part of the PXI Arbitrary Waveform Generators category and is modeled as PXIe-5413. This device is a PXI Waveform Generator capable of delivering up to 20 MHz frequency support. It is designed to facilitate a wide range of applications with its 20 MHz, 16 bits, 800 MS/s, 2 Channels, 128 MB specifications.
The PXIe-5413 boasts an impressive step response rise time of 14.8 ns, ensuring rapid response to changes. With an arbitrary waveform size ranging from 2 samples to 64,000,000 samples, it accommodates a broad spectrum of waveform complexities and lengths.
When it comes to sampling rate, users have flexibility depending on the status of the digital filter. With the digital filter enabled, the user sample rate can vary from 5.6 µS/s to 200 MS/s. Disabling the digital filter broadens the range, offering rates from 3.125 MS/s to 200 MS/s.
The frequency step size of 2.84 µHz allows for precise adjustments, making it suitable for applications requiring fine-tuning of frequency outputs. The device also supports up to 8,192 waveform points, enabling the generation of complex waveforms.
Its reference clock frequency is set at 100 MHz (<±25 ppm), ensuring accurate timing. The sample clock rate can reach up to 800 MHz, allowing for high-speed waveform generation.
Furthermore, the PXIe-5413 is equipped with a PFI I/O frequency range of 0 MHz to 25 MHz, providing versatility in interfacing with external devices. This wide range of technical specifications makes the PXIe-5413 an ideal solution for applications requiring high-performance arbitrary waveform generation.
Specification | Details |
---|---|
Part Number | 785114-01 |
Category | PXI Arbitrary Waveform Generators |
Model | PXIe-5413 |
Description | PXIe-5413 PXI Waveform Generator, 20 MHz, 16 bits, 800 MS/s, 2 Channels, 128 MB |
Frequency Support | Up to 20 MHz |
Step Response Rise Time | 14.8 ns |
Arbitrary Waveform Size | 2 samples to 64,000,000 samples |
User Sample Rate (Digital Filter Enabled) | 5.6 µS/s to 200 MS/s |
User Sample Rate (Digital Filter Disabled) | 3.125 MS/s to 200 MS/s |
Frequency Step Size | 2.84 µHz |
Waveform Points | 8,192 |
Reference Clock Frequency | 100 MHz (<±25 ppm) |
Sample Clock Rate | 800 MHz |
PFI I/O Frequency Range | 0 MHz to 25 MHz |
Maximum Input
Question 1: What is the max frequency of the PXIe-5413? Question 2: How many channels does the PXIe-5413 have? Question 3: What is the max sample rate of the PXIe-5413? Question 4: What is the max waveform size for PXIe-5413? Question 5: What is the reference clock frequency of PXIe-5413? |