Description
The National Instruments PCI-6284 Multifunction DAQ, with part number 779110-01, is a high-performance M Series Multifunction Data Acquisition Device designed for a variety of applications. It features a single analog trigger with multiple operating modes, including analog window, analog edge with hysteresis, and analog edge triggering, to accommodate different triggering requirements. The analog trigger boasts an approximate resolution of 10 bits and an accuracy of ±1%, ensuring precise signal processing.
For timing and counting tasks, this DAQ device is equipped with two general-purpose counter/timers, each with a 32-bit resolution. These counter/timers are versatile and can be used for edge counting, measuring the separation between two edges, as well as for period, semi-period, and pulse counting applications. The device also offers a base clock precision of roughly 50 parts per million (ppm), with internal base clock frequencies of 0.1 MHz, 20 MHz, and 80 MHz, and an external base clock frequency range from 0 MHz to 20 MHz.
Compliance with stringent industry standards for electrical equipment used in measurement, control, and laboratory contexts is a hallmark of the National Instruments PCI-6284, which also meets EMC standard requirements. This ensures that the device not only delivers accurate and reliable performance but also adheres to safety and environmental regulations.
Feature | Specification |
---|---|
Product Name | National Instruments PCI-6284 Multifunction DAQ |
Part Number | 779110-01 |
Type | M Series Multifunction Data Acquisition Device |
Analog Triggers | 1 Analog Trigger |
Analog Trigger Modes | Analog window, analog edge with hysteresis, analog edge |
Analog Trigger Resolution | Approximately 10 bits |
Analog Trigger Accuracy | ±1% |
Counter/Timers | 2 General Purpose, 32-bit Resolution |
Counter/Timer Functions | Edge counting, two edge separation, period, semi period, pulse counting |
Base Clock Precision | Approximately 50 ppm |
Internal Base Clock Frequency | 0.1 MHz, 20 MHz, 80 MHz |
External Base Clock Frequency | 0 MHz to 20 MHz |
Compliance with Standards | Electrical equipment for measurement, control, and laboratory use |
EMC Standards | Meets requirements |
Question 1: What are the various applications for which the National Instruments PCI-6284 Multifunction DAQ is designed, and what specific features support its accuracy and versatility in signal processing and timing tasks?
Answer 1: The National Instruments PCI-6284 Multifunction DAQ can support an external base clock frequency range from 0 MHz to 20 MHz.
Question 2: What is the range of the external base clock frequency that the National Instruments PCI-6284 Multifunction DAQ can support?
Answer 2: The analog trigger on the National Instruments PCI-6284 Multifunction DAQ offers multiple operating modes, including analog window, analog edge with hysteresis, and analog edge triggering, and it features an approximate resolution of 10 bits with an accuracy of ±1%.
Question 3: What are the different operating modes available for the analog trigger on the National Instruments PCI-6284 Multifunction DAQ, and what is its approximate resolution and accuracy?
Answer 3: The National Instruments PCI-6284 Multifunction DAQ with part number 779110-01 is a high-performance device with key features that include a single analog trigger with multiple operating modes for various triggering requirements, an analog trigger resolution of approximately 10 bits and an accuracy of ±1%, two general-purpose 32-bit counter/timers for timing and counting tasks, and a base clock precision of about 50 ppm with multiple internal and external frequency options; furthermore, it complies with stringent industry
Question 4: What are the key features and compliance standards of the National Instruments PCI-6284 Multifunction DAQ with part number 779110-01?
Answer 4: The National Instruments PCI-6284 Multifunction DAQ is designed for diverse applications requiring precise signal processing and timing tasks, featuring a single analog trigger with multiple modes for different triggering requirements and a resolution of approximately 10 bits with an accuracy of ±1% for accuracy in signal processing, as well as two general-purpose 32-bit counter/timers for versatile timing and counting operations, supported by a base clock precision of about 50 ppm and variable internal and external clock frequencies to ensure versatility and reliability
Question 5: What are the features and capabilities of the National Instruments PCI-6284 Multifunction DAQ, and how does it ensure compliance with industry standards for measurement and control equipment?
Answer 5: The National Instruments PCI-6284 Multifunction DAQ features a single analog trigger with various operating modes for diverse triggering needs, a 10-bit resolution, ±1% accuracy, and two 32-bit counter/timers for versatile timing and counting tasks, with a base clock precision of about 50 ppm and multiple internal and external base clock frequencies; it ensures compliance with industry standards for measurement and control equipment through adherence to rigorous EMC standards, thereby guaranteeing both performance accuracy and conformity with safety and