img

151967E-01L

This device, with part numbers 782376-01, 150818E-02L, offers 80 MHz bandwidth, a 65 MHz to 6 GHz frequency range, and compatibility with various software.

In Stock | Ships Today

img

    Description

    The provided technical specification outlines the key features and details of a high-performance device with part numbers 782376-01 and 150818E-02L. This device boasts a bandwidth of 80 MHz, ensuring ample capacity for processing signals within a frequency range of 65 MHz to 6 GHz. Precision in operation is highlighted by its timing resolution being finer than 1 Hz, offering exceptional detail in time-sensitive applications.

    The initial adjustment accuracy stands at ±200 × 109, which, when combined with an aging factor of ±1 × 10-6 per year, ensures long-term reliability and stability. The device’s amplitude range extends from the average noise level up to +30 dBm, providing a wide dynamic range for signal generation and analysis. Furthermore, the RF reference level resolution/range is ≥60 dB in 1 dB nominal steps, allowing for precise adjustments to the reference level.

    Connection to the device is facilitated through an SMA (female) connector, with an input impedance of 50 Ω nominal (AC coupled). This makes it compatible with a variety of RF systems and equipment. The device boasts extensive software compatibility, including NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabWindows/CVI, and Microsoft Visual C++, ensuring it can be integrated into numerous software environments for a broad range of applications.

    Additionally, it features a VHDCI digital I/O connector with a voltage range of -0.5 V to 4.5 V, providing flexible options for digital interfacing. The available calibration options include both NIST accredited (via third party) and Basic in-house (unaccredited)

    Question 1: What is the bandwidth of the PXIe-5644?
    Answer 1: 80 MHz

    Question 2: What frequency range does the PXIe-5644 cover?
    Answer 2: 65 MHz to 6 GHz

    Question 3: What is the initial adjustment accuracy of the PXIe-5644?
    Answer 3: ±200 × 10^9

    Question 4: What software is compatible with the PXIe-5644?
    Answer 4: NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabWindows/CVI, Visual C++

    Question 5: What is the input impedance of the PXIe-5644’s SMA connector?
    Answer 5: 50 Ω nominal (AC coupled)

    Specification Details
    Part Number 782376-01, 150818E-02L
    Bandwidth 80 MHz
    Frequency Range 65 MHz to 6 GHz
    Timing Resolution <1 Hz
    Initial Adjustment Accuracy ±200 × 109
    Aging Factor ±1 × 10-6 per year
    Amplitude Range Average noise level to +30 dBm
    RF Reference Level Resolution/Range ≥60 dB in 1 dB nominal steps
    Connector Type SMA (female)
    Input Impedance 50 Ω nominal (AC coupled)
    Software Compatibility NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabWindows/CVI, Microsoft Visual C++
    Digital I/O Connector VHDCI
    Digital I/O Voltage Range -0.5 V to 4.5 V
    Calibration Options NIST accredited (via third party), Basic in-house (unaccredited)