Description
The products with Part Numbers 782376-01 and 150818E-02L are models PXIe-5644 and PXIe-5644R, respectively, designed to meet a wide range of testing and measurement needs. These models boast a significant Bandwidth of 80 MHz, capable of handling signals within a Frequency Range from 65 MHz to 6 GHz. Precision is ensured through an Initial Adjustment Accuracy of ±200 × 109, and reliability over time is guaranteed with an Aging Factor of ±1 × 10-6 per year.
Their Amplitude Range extends from the average noise level to +30 dBm, accommodating a wide spectrum of signal strengths. The RF Reference Level Resolution/Range is remarkably sensitive, with ≥60 dB in 1 dB nominal steps, ensuring precise control over signal levels. Additionally, these models feature a Timing Resolution of less than 1 Hz, allowing for highly accurate time measurements.
Connection to these devices is made through a Connector Type of SMA (female), 50 Ω nominal input impedance, which is AC coupled, ensuring compatibility with a wide range of equipment. They are designed to work seamlessly with a variety of software, including NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabVIEW FPGA Module, and LabVIEW Real-Time Module (optional), offering flexibility in application and integration into existing systems.
To maintain accuracy and performance, Calibration is available, with a recommended calibration period of annually or every two years. Furthermore, these models come equipped with a Digital
| Specification | Detail |
|---|---|
| Part Numbers | 782376-01, 150818E-02L |
| Model | PXIe-5644 / PXIe-5644R |
| Bandwidth | 80 MHz |
| Frequency Range | 65 MHz to 6 GHz |
| Initial Adjustment Accuracy | ±200 × 109 |
| Aging Factor | ±1 × 10-6 per year |
| Amplitude Range | Average noise level to +30 dBm |
| RF Reference Level Resolution/Range | ≥60 dB in 1 dB nominal steps |
| Timing Resolution | < 1 Hz |
| Connector Type | SMA (female), 50 Ω nominal input impedance, AC coupled |
| Software Compatibility | NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabVIEW FPGA Module, LabVIEW Real-Time Module (optional) |
| Calibration | Available, with recommended calibration period of annually or every two years |
| Digital I/O Connector | VHDCI, -0.5 V to 4.5 V absolute maximum input range, 10 kΩ
Question 1: What is the bandwidth of PXIe-5644/R? Question 2: What frequency range does PXIe-5644 support? Question 3: What is the aging factor of PXIe-5644/R? Question 4: What type of connectors do PXIe-5644 models use? Question 5: What software is compatible with PXIe-5644/R? |