Description
The product features part numbers 782376-01 and 150818E-02L, ensuring a wide range of applications and compatibility. It boasts an impressive bandwidth of 80 MHz, suitable for various high-frequency applications. The frequency range spans from 65 MHz to 6 GHz, covering a broad spectrum for diverse applications.
The timing resolution is less than 1 Hz, providing precise control over timing measurements. The initial adjustment accuracy is rated at ±200 × 109, ensuring reliable and accurate performance from the start. The aging factor is remarkably low, at ±1 × 10-6 per year, highlighting the device’s stability and longevity.
Its amplitude range extends from the average noise level up to +30 dBm, offering versatility in signal amplitude settings. The RF reference level resolution/range is ≥60 dB in 1 dB nominal steps, allowing for fine adjustments to meet specific requirements. The device features an SMA (female), 50 Ω nominal impedance connector type, ensuring compatibility with standard RF equipment.
Software compatibility includes NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabWindows/CVI, and Microsoft Visual C++, providing a wide range of options for integration and application development. Calibration is available, with recommendations for it to be conducted annually or every two years to maintain optimal performance.
The Digital I/O connector utilizes a VHDCI connector, facilitating easy and reliable connections. The absolute maximum input range for the Digital I/O is -0.5 V to 4.5 V, accommodating a variety of digital signals. The nominal input impedance for the Digital I/O is specified, ensuring compatibility and optimal performance with connected digital devices.
| Specification | Detail |
|---|---|
| Part Numbers | 782376-01, 150818E-02L |
| Bandwidth | 80 MHz |
| Frequency Range | 65 MHz to 6 GHz |
| Timing Resolution | <1 Hz |
| Initial Adjustment Accuracy | ±200 × 109 |
| Aging Factor | ±1 × 10-6 per year |
| Amplitude Range | Average noise level to +30 dBm |
| RF Reference Level Resolution/Range | ≥60 dB in 1 dB nominal steps |
| Connector Type | SMA (female), 50 Ω nominal impedance |
| Software Compatibility | NI-RFmx, NI-RFSA, NI-RFSG, LabVIEW, LabWindows/CVI, Microsoft Visual C++ |
| Calibration | Available, recommended annually or every two years |
| Digital I/O Connector | VHDCI connector |
| Absolute Maximum Input Range (Digital I/O) | -0.5 V to 4.5 V |
| Nominal Input Impedance (Digital I/O) | Question 1: What are the part numbers for PXIe-5644? Answer 1: 782376-01 and 150818E-02L. Question 2: What is the bandwidth of PXIe-5644? Question 3: What frequency range does PXIe-5644 cover? Question 4: Which software is compatible with PXIe-5644? Question 5: What is the aging factor of PXIe-5644? |