The National Instruments PXIe-5693 is a high-performance PXI RF Preselector Module designed for spectrum monitoring tasks that require both preselection and pre-amplification capabilities. It carries the part number 782549-01 and falls under the category of VSA/VSG Sig Conditioning & Accessories.
This module is engineered to cover a wide frequency bandwidth from 20 MHz to 7 GHz, ensuring it can handle a broad range of signals. A key feature of the PXIe-5693 is its spectrum monitoring receiver function, enabling it to effectively manage and analyze spectrum in real-time environments.
To facilitate precise filtering, the PXIe-5693 is equipped with sixteen highly tuned sub-octave bandpass filters, which are crucial for isolating specific frequency bands and improving signal clarity. Moreover, the module boasts a self-calibration capability with a built-in calibration tone, ensuring accurate and reliable performance over time.
For signals that do not require preselection, the module offers a bypass signal path frequency range from DC to 30 MHz. Connectivity is facilitated using SMA-to-SMA coaxial cables, providing a robust and reliable connection interface for various test setups.
The PXIe-5693 is designed to be compact and efficient, requiring only one slot in a PXI Express Chassis. This feature allows for easy integration into existing setups without the need for significant reconfiguration or additional space.
| Specification | Detail |
|---|---|
| Part Number | 782549-01 |
| Model | PXIe-5693 |
| Category | VSA/VSG Sig Conditioning & Accessories |
| Description | National Instruments PXIe-5693 PXI RF Preselector Module |
| Frequency Bandwidth | 20 MHz to 7 GHz |
| Function | Spectrum monitoring receiver with preselection and pre-amplification capabilities |
| Built-in Filters | Sixteen highly tuned sub-octave bandpass filters |
| Calibration | Self-calibration with built-in calibration tone |
| Bypass Signal Path Frequency Range | DC to 30 MHz |
| Connection Type | SMA-to-SMA coaxial cables |
| Chassis Slot Requirement | One slot in a PXI Express Chassis |
Question 1: What is the frequency range of the PXIe-5693?
Answer 1: 20 MHz to 7 GHz
Question 2: How many filters does the PXIe-5693 have?
Answer 2: Sixteen sub-octave bandpass filters
Question 3: Does the PXIe-5693 have a self-calibration feature?
Answer 3: Yes, with a built-in calibration tone
Question 4: What is the bypass signal path frequency range?
Answer 4: DC to 30 MHz
Question 5: How many PXI Express Chassis slots does the PXIe-5693 require?
Answer 5: One slot