img

199149D-01L

The PXIe-6124 is a PXI Multifunction DAQ with 4 differential analog inputs, 16-bit resolution, and supports IF digitization and ADSL testing.

In Stock | Ships Today

img

    Description

    The 780536-01 is a PXI Multifunction DAQ device, specifically model PXIe-6124, designed for a wide range of applications including IF digitization, ISDN, ADSL, and POTS testing. This device offers 4 differential analog inputs with a resolution of 16 bits, ensuring high-quality data acquisition. Each channel can sample at a rate of 4 MS/s, providing the capability to capture fast transient signals with an input bias current of ± 10 pA.

    It features an impressive inter-channel slew of 5 ns, allowing for rapid data collection across multiple channels without significant delay. For output, the PXIe-6124 includes 2 voltage channels capable of a sampling rate of 4 MS/s for a single channel and 2.5 MS/s when both channels are used. This flexibility in sampling rate supports a variety of testing scenarios. The output voltage range of ± 10 V coupled with an output impedance of 0.4 ohms and an output current drive of ± 5 mA enables the device to interface with a wide range of sensors and actuators.

    Protection features include an overdrive protection voltage of ± 25 V and an overdrive current of 10 mA, safeguarding the device against unexpected voltage spikes. The analog outputs have a swift slew rate of 20 V/µs, ensuring rapid response to control commands. Moreover, power-on glitches are minimized to 1.5 V for 10 µs, reducing the risk of erroneous measurements at startup.

    The PXIe-6124 is equipped with a built-in 32-bit counter, expanding its utility for precise timing and event counting tasks. It also supports digital triggering, enhancing its flexibility and enabling it to integrate seamlessly into complex test setups. This combination of features makes the PXIe-6124 an ideal solution for a broad spectrum of data acquisition and control applications.

    Specification Details
    Part Number 780536-01
    Category PXI Multifunction DAQ
    Model PXIe-6124
    Analog Inputs 4 differential
    Resolution 16 bits
    Sample Rate (per channel) 4 MS/s
    Input Bias Current ± 10 pA
    Inter-channel Slew 5 ns
    Analog Output Channels 2 voltage channels
    Sampling Rate (1 channel) 4 MS/s
    Sampling Rate (2 channels) 2.5 MS/s
    Output Voltage Range ± 10 V
    Output Impedance 0.4 ohms
    Output Current Drive ± 5 mA
    Overdrive Protection Voltage ± 25 V
    Overdrive Current 10 mA
    Slew Rate 20 V/µs
    Power On Glitches 1.5 V for 10 µs
    Built-in Counter 32 bits
    Applications IF digitization, ISDN, ADSL, POTS testing
    Digital Triggering Supported

    Question 1: What resolution is the PXIe-6124?
    Answer 1: 16 bits

    Question 2: How many differential analog inputs does the PXIe-6124 have?
    Answer 2: 4

    Question 3: What is the maximum sampling rate per channel on the PXIe-6124?
    Answer 3: 4 MS/s

    Question 4: What protection voltage does the PXIe-6124 support?
    Answer 4: ± 25 V

    Question 5: Does the PXIe-6124 support digital triggering?
    Answer 5: Yes