Description
The Part Number 781053-01 identifies a PXI Multifunction DAQ known as the PXIe-6356, manufactured by National Instruments. This device is notable for its high-performance capabilities in data acquisition.
It boasts an impressive sampling rate of 1.25MS/s per channel, allowing for precise and timely data collection across its 8 simultaneous analog input channels. Each of these channels supports 16-Bit resolution, ensuring detailed data capture for analysis.
Moreover, the PXIe-6356 is equipped with digital I/O capabilities and 32-Bit counters, enhancing its versatility in various applications. It utilizes the NI-STC3 system for efficient timing and synchronization, further cementing its utility in complex data acquisition tasks.
This device operates at a maximum bandwidth of 250 MB/s and connects via a PCI Express interface, highlighting its fast and reliable data transfer capabilities. It is designed for a wide array of applications including IF digitization, ultrasound, ADSL, ISDN, POTS manufacturing test, high-energy physics, sonar testing, and transient recording, making it a versatile tool for professionals in various fields.
Compatibility with several drivers is ensured, including NI-DAQmx, LabWindows/CVI 7.x, LabView 8.2, LabVIEW Signal Express 1.x, Microsoft Visual Studio .NET, and C/C++, offering flexibility in programming and customization. Lastly, it supports multiple operating systems such as Windows 7, Vista, XP, and 2000, ensuring wide accessibility and user convenience.
| Feature | Description |
|---|---|
| Part Number | 781053-01 |
| Category | PXI Multifunction DAQ |
| Model | PXIe-6356 |
| Manufacturer | National Instruments |
| Sampling Rate | 1.25MS/s per channel |
| Analog Input Channels | 8 simultaneous |
| Analog Input Resolution | 16-Bit |
| Digital I/O | Yes |
| Counters | 32-Bit |
| Timing and Synchronization | NI-STC3 system |
| Bandwidth | 250 MB/s maximum |
| Interface | PCI Express |
| Applications | IF digitization, ultrasound, ADSL, ISDN, POTS manufacturing test, high-energy physics, sonar testing, transient recording |
| Driver Compatibility | NI-DAQmx, LabWindows/CVI 7.x, LabView 8.2, LabVIEW Signal Express 1.x, Microsoft Visual Studio .NET, C/C++ |
| Operating Systems | Windows 7/Vista/XP/2000 |