img

PXI-2571

The National Instruments PXI-2571 PXI Relay Module, part number 778572-71, is a 66-channel, high-density SPDT relay module with a voltage rating up to 100 VDC/100 VAC, current rating

In Stock | Ships Today

img

    Description

    The National Instruments PXI-2571 PXI Relay Module, with Part Number 778572-71, is a versatile 66-channel relay module designed for high-density switching applications. Each of its channels utilizes SPDT (Form C) relays, providing a variety of terminal types including Normally Closed (NC), Normally Open (NO), and Common (COM) to accommodate different circuit configurations. This module can handle voltages up to 100 VDC/100 VAC and currents up to 1 A, suitable for a wide range of signal levels.

    With its capacity to store up to 1024 scan instructions, the PXI-2571 allows for extensive test sequence automation, while the integrated Switch Control Circuitry (SCC) efficiently manages the opening and closing of relays for reliable operation. The module comes with software that simplifies setup by automatically configuring the hardware and downloading the scan list directly into the module’s memory, which streamlines the testing process and enhances performance.

    Additionally, the PXI-2571’s capability to interface with measurement devices ensures that signals are correctly routed before measurements begin, and it supports waiting for an external trigger to start scanning, ensuring synchronization with other test instruments in a system. This level of integration and automation makes the National Instruments PXI-2571 an essential component for advanced automated test equipment (ATE) setups.

    Attribute Details
    Product Name National Instruments PXI-2571 PXI Relay Module
    Part Number 778572-71
    Channel Count 66-channel
    Relay Type SPDT (Form C) relays
    Terminal Types Normally Closed (NC), Normally Open (NO), Common (COM)
    Voltage Rating Up to 100 VDC/100 VAC
    Current Rating Up to 1 A
    Scan List Capacity Up to 1024 instructions
    Switch Control Circuitry (SCC) Manages opening and closing of relays
    Software Configuration Automatic configuration and scan list download
    Measurement Device Triggering Ensures correct signal routing and waiting for external trigger

    Question 1: How does the integrated Switch Control Circuitry in the National Instruments PXI-2571 Relay Module contribute to its reliability during high-density switching applications?
    Answer 1: The integrated Switch Control Circuitry (SCC) in the National Instruments PXI-2571 Relay Module manages the opening and closing of relays with precision, ensuring consistent and reliable relay operation throughout high-density switching applications.

    Question 2: What are the voltage and current handling capabilities of the National Instruments PXI-2571 PXI Relay Module, and how does its support for 1024 scan instructions contribute to test sequence automation?
    Answer 2: The SPDT relays on the National Instruments PXI-2571 PXI Relay Module support Normally Closed (NC), Normally Open (NO), and Common (COM) terminal connections, and the module can handle voltages up to 100 VDC/100 VAC and currents up to 1 A.

    Question 3: What types of terminal connections are provided by each channel on the National Instruments PXI-2571 PXI Relay Module, and what voltage and current specifications does it support?
    Answer 3: Each channel on the National Instruments PXI-2571 PXI Relay Module provides Normally Closed (NC), Normally Open (NO), and Common (COM) terminal connections, and supports voltage specifications up to 100 VDC/100 VAC and current specifications up to 1 A.

    Question 4: What are the applications of the SPDT relays and the capabilities of the Switch Control Circuitry (SCC) in the National Instruments PXI-2571 PXI Relay Module for automating test sequences?
    Answer 4: The National Instruments PXI-2571 PXI Relay Module can handle voltages up to 100 VDC/100 VAC and currents up to 1 A, and its support for 1024 scan instructions contributes to test sequence automation by allowing users to predefine a sequence of relay operations, thereby facilitating complex testing procedures without the need for continuous manual intervention.

    Question 5: What types of terminal connections are supported by the SPDT relays on the National Instruments PXI-2571 PXI Relay Module, and what are its voltage and current handling capabilities?
    Answer 5: The SPDT relays in the National Instruments PXI-2571 PXI Relay Module are used to accommodate different circuit configurations by providing Normally Closed (NC), Normally Open (NO), and Common (COM) terminal types, which are essential for high-density switching applications, while the Switch Control Circuitry (SCC) efficiently manages the opening and closing of these relays, allowing for the automation of complex test sequences by storing and executing up to 1024 scan instructions, ensuring reliable operation and synchronization