The National Instruments PXI-2585 PXI Multiplexer Switch Module, with Part Number 778572-85, is designed to handle a current rating of 12 A and is configured as a 1-Wire, 10-Channel Multiplexer. This module is capable of withstanding a maximum switching voltage of 300 V between channels and also from channel-to-ground, adhering to Measurement Category II standards.
It showcases a robust maximum switching power capacity in AC systems of up to 3 kVA (up to 60 Hz) per channel. The module utilizes electromechanical single-side stable relays with silver-nickel relay contact material, ensuring durability and high performance. These relays have a maximum actuation time of 15.4 milliseconds, and the relay life expectancy is rated at 1 × 107 cycles mechanically and 1 × 105 cycles electrically at 30V DC, 10A, with a lower electrical lifespan of 3 × 104 cycles at 30V DC, 12A.
Connectivity is facilitated by a Positronic GMCT series plug I/O connector, which features 20 positions, providing secure and reliable connections for various applications.
Question 1: What is the maximum switching power capacity of the National Instruments PXI-2585 PXI Multiplexer Switch Module and what type of relays does it utilize?
Answer 1: The National Instruments PXI-2585 PXI Multiplexer Switch Module has a maximum switching power capacity of 3 kVA in AC systems, and it uses silver-nickel relay contact material.
Question 2: What is the maximum switching power capacity of the National Instruments PXI-2585 PXI Multiplexer Switch Module in AC systems, and what type of relay contact material does it use?
Answer 2: The relays in the National Instruments PXI-2585 PXI Multiplexer Switch Module with Part Number 778572-85 have a mechanical life expectancy of 1 × 10^7 cycles and an electrical life expectancy of 1 × 10^5 cycles at 30V DC, 10A, and it uses a Positronic GMCT series plug I/O connector with 20 positions.
Question 3: What are the maximum switching power capacity and actuation time of the National Instruments PXI-2585 PXI Multiplexer Switch Module, and what type of relay contact material does it employ?
Answer 3: The maximum switching power capacity of the National Instruments PXI-2585 PXI Multiplexer Switch Module is 3 kVA in AC systems up to 60 Hz per channel, and it utilizes electromechanical single-side stable relays with silver-nickel contact material.
Question 4: What is the electrical life expectancy of the National Instruments PXI-2585 PXI Multiplexer Switch Module’s electromechanical relays when operating at 30V DC and 12A?
Answer 4: The electrical life expectancy of the National Instruments PXI-2585 PXI Multiplexer Switch Module’s electromechanical relays when operating at 30V DC and 12A is 30,000 cycles.
Question 5: What is the mechanical and electrical life expectancy of the relays in the National Instruments PXI-2585 PXI Multiplexer Switch Module with Part Number 778572-85, and what type of I/O connector does it use?
Answer 5: The National Instruments PXI-2585 PXI Multiplexer Switch Module has a maximum switching power capacity of 3 kVA at up to 60 Hz per channel, an actuation time of 15.4 milliseconds, and employs silver-nickel relay contact material.
Attribute | Value |
---|---|
Product Name | National Instruments PXI-2585 PXI Multiplexer Switch Module |
Part Number | 778572-85 |
Current Rating | 12 A |
Configuration | 1-Wire, 10-Channel Multiplexer |
Maximum Switching Voltage | 300 V channel-to-channel, 300 V channel-to-ground (Measurement Category II) |
Maximum Switching Power (AC) | 3 kVA (up to 60 Hz) per channel |
Relay Type | Electromechanical single-side stable relays |
Relay Contact Material | Silver-nickel |
Actuation Time | 15.4 milliseconds maximum |
Relay Life (Mechanical) | 1 × 107 cycles |
Relay Life (Electrical at 30V DC, 10A) | 1 × 105 cycles |
Relay Life (Electrical at 30V DC, 12A) | 3 × 104 cycles |
I/O Connector | Positronic GMCT series plug, 20-positions |