Description
The NI PXI-5900 Differential Preamplifier, with part number 196368C-01L (780166-01), is a crucial component in the category of PXI Oscilloscopes/Digitizers. This model, PXI-5900, is specifically designed for enhancing the performance of the PXI-5922 Digitizer.
It features 2 input channels, providing versatility in measurement capabilities. The preamplifier supports various input couplings, including GND, AC, and DC, allowing for a wide range of signal types to be accurately measured. The input impedance is notably precise at 50 Ω ±2% and is software-selectable, offering flexibility and ease of use.
Connection to the preamplifier is facilitated through BNC input and SMB output connectors, ensuring compatibility with a variety of devices and setups. The vertical gain is finely tuned to 0.25 ±0.2%, and it boasts a minimal zero input offset error of 500 μV, enhancing measurement accuracy.
Its passband flatness is within 1 dB, ensuring uniform performance across the supported frequency range. The Common-Mode Rejection Ratio (CMRR) is impressively high at 70 dB at 60 Hz, significantly reducing the noise level and improving signal fidelity. The preamplifier’s slew rate is 100 V/μs, indicating its ability to handle rapid changes in signal amplitude without distortion.
This model is compatible with NI-SCOPE 3.5.1, and NI Measurement & Automation Explorer (MAX) software, making it a versatile tool for a wide range of applications. Despite its powerful capabilities, the device maintains a light weight of 173 grams, making it an efficient and portable option for any setup.
| Specification | Detail |
|---|---|
| Part Number | 196368C-01L (780166-01) |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5900 |
| Description | NI PXI-5900 Differential Preamplifier for PXI-5922 Digitizer |
| Input Channels | 2 |
| Input Coupling | GND, AC, DC |
| Input Impedance | 50 Ω ±2% (software-selectable) |
| Connectors | BNC input, SMB output |
| Vertical Gain | 0.25 ±0.2% |
| Zero Input Offset Error | 500 μV |
| Passband Flatness | 1 dB |
| Common-Mode Rejection Ratio | 70 dB at 60 Hz |
| Slew Rate | 100 V/μs |
| Software Compatibility | NI-SCOPE 3.5.1, NI Measurement & Automation Explorer (MAX) |
| Weight | 173 grams
Question 1: What is the part number for the NI PXI-5900? Question 2: How many input channels does the PXI-5900 have? Question 3: What is the input impedance of the PXI-5900? Question 4: What software is the PXI-5900 compatible with? Question 5: What’s the CMRR for the PXI-5900 at 60 Hz? |