The National Instruments PXI-6070E Multifunction DAQ, with part number 777060-01, offers a 12-bit resolution, a maximum sampling rate of 1.25 MS/s, up to 64 single-ended analog
The National Instruments PXI-6070E Multifunction DAQ, with part number 777060-01, offers a maximum sampling rate of up to 1.25 MS/s and a resolution of 12-bit, making it highly efficient for a variety of data acquisition tasks. It can handle 16 or 64 single-ended analog inputs and is capable of streaming to disk at rates of up to 1.25 MS/s.
Equipped with two 12-bit analog outputs and two 24-bit, 20 MHz counter/timers, this DAQ device also includes eight digital I/O lines for expanded connectivity options. The unit utilizes a 68-pin male 0.050 D-type I/O connector and delivers 250 V of functional isolation.
Operation of the PXI-6070E is supported by NIDAQmx driver software and is compatible with various application development environments (ADEs) including LabVIEW, LabWindows/CVI, and Measurement Studio. To ensure optimal performance, a recommended warm-up time of 15 minutes is advised, along with a calibration interval of at least once a year. The device is lightweight, weighing just 7.1 oz, which contributes to its ease of installation and handling.
Specification
Detail
Product
National Instruments PXI-6070E Multifunction DAQ
Part Number
777060-01
Maximum Sampling Rate
1.25 MS/s
Resolution
12-bit
Number of Analog Inputs
16 or 64 single-ended
Streaming to Disk Rate
Up to 1.25 MS/s
Analog Outputs
Two 12-bit
Counter/Timers
Two 24-bit, 20 MHz
Digital I/O Lines
Eight
I/O Connector
68-pin male 0.050 D-type
Functional Isolation
250 V
Driver Software
NIDAQmx
Compatible ADEs
LabVIEW, LabWindows/CVI, Measurement Studio
Recommended Warm-Up Time
15 minutes
Calibration Interval
At least once a year
Weight
7.1 oz
Question 1: Considering its specifications and supported software, what kind of applications can benefit from using the National Instruments PXI-6070E Multifunction DAQ? Answer 1: The recommended calibration interval for the National Instruments PXI-6070E Multifunction DAQ to ensure its optimal performance is at least once a year.
Question 2: What features and specifications make the National Instruments PXI-6070E Multifunction DAQ ideal for various data acquisition tasks, and what are its recommended software and maintenance practices? Answer 2: The National Instruments PXI-6070E Multifunction DAQ, with its high sampling rate, multiple input/output channels, and compatibility with software such as LabVIEW, LabWindows/CVI, and Measurement Studio, is well-suited for a wide range of applications including automated testing, laboratory research, industrial control and monitoring, and complex data logging and analysis tasks.
Question 3: What is the data throughput capability and isolation voltage specification of the National Instruments PXI-6070E Multifunction DAQ with part number 777060-01? Answer 3: The National Instruments PXI-6070E Multifunction DAQ can handle 16 or 64 single-ended analog inputs and is capable of streaming to disk at rates of up to 1.25 MS/s; it is compatible with NIDAQmx driver software and supports various application development environments including LabVIEW, LabWindows/CVI, and Measurement Studio.
Question 4: What are the analog input capabilities and streaming to disk rate of the National Instruments PXI-6070E Multifunction DAQ, and what software and ADEs is it compatible with? Answer 4: The National Instruments PXI-6070E Multifunction DAQ with part number 777060-01 is capable of streaming to disk at rates of up to 1.25 MS/s and offers a functional isolation voltage of 250 V.
Question 5: What is the recommended calibration interval for the National Instruments PXI-6070E Multifunction DAQ to ensure its optimal performance? Answer 5: The National Instruments PXI-6070E Multifunction DAQ is ideal for a range of data acquisition tasks due to its high sampling rate of up to 1.25 MS/s, 12-bit resolution, the ability to handle 16 or 64 single-ended analog inputs, and the capability to stream to disk at rates of up to 1.25 MS/s. It is also equipped with two 12-bit analog outputs, two 24-bit, 20 MHz counter/timers