Description
The National Instruments PXI-6238 Digital Multifunction I/O Module, with part number 779624-01, features 16 analog inputs with a resolution of 16 bits and a sampling rate of 1.25 MS/s, alongside 2 analog outputs.
It also includes 6 digital inputs and 4 digital outputs for versatile digital interfacing. The device supports bank isolation for enhanced signal integrity and auto-calibration to maintain accuracy over time and environmental conditions.
Calibration constants are securely stored on an onboard EEPROM that is non-modifiable, ensuring factory settings remain intact, while also providing a client modifiable area of the EEPROM for self-calibration constants.
The module is compatible with a wide range of sensors, including strain gauges, thermocouples, thermistors, angular encoders, linear encoders, and resistance temperature detectors (RTDs). Each module contains one analog-to-digital converter (ADC) that works with the internal multiplexers (MUX) to route one AI channel at a time to the ADC.
The inclusion of the NI Programmable Gain Instrumentation Amplifier (NI-PGIA) minimizes settling times for all input ranges, ensuring that the maximum resolution of the ADC is utilized for precise measurements.
Property | Value |
---|---|
Part Number | 779624-01 |
Description | National Instruments PXI-6238 Digital Multifunction I/O Module |
Analog Inputs (AI) | 16 Channels (16 Bits, 1.25 MS/s) |
Analog Outputs (AO) | 2 Channels |
Digital Inputs (DI) | 6 Channels |
Digital Outputs (DO) | 4 Channels |
Bank Isolation | Yes |
Auto-Calibration | Supported |
Factory-Calibration Constants Storage | Onboard EEPROM (non-modifiable) |
Self-Calibration Constants Storage | Client modifiable area of the EEPROM |
Common Sensors Supported | Strain gauges, Thermocouples, Thermistors, Angular Encoders, Linear Encoders, RTDs |
ADC (Analog-to-Digital Converter) | 1 per Module |
Multiplexers (MUX) | Routes one AI channel at a time to the ADC |
NI-PGIA (Programmable Gain Instrumentation Amplifier) | Minimizes settling times for all input ranges |
Question 1: What are the benefits of the bank isolation feature and auto-calibration on the National Instruments PXI-6238 Digital Multifunction I/O Module, and how do they improve the module’s performance?
Answer 1: The benefits of the bank isolation feature on the National Instruments PXI-6238 Digital Multifunction I/O Module include enhanced signal integrity by reducing electrical noise and crosstalk between channels, while the auto-calibration function maintains measurement accuracy over time and varying environmental conditions, ensuring the module consistently performs precise data acquisition and signal processing.
Question 2: What are the key features and capabilities of the National Instruments PXI-6238 Digital Multifunction I/O Module, specifically in terms of its analog and digital I/O, on-board memory, and compatibility with various sensors?
Answer 2: The National Instruments PXI-6238 Digital Multifunction I/O Module is particularly suitable for interfacing with a variety of sensors due to its 16 analog inputs, 2 analog outputs, 6 digital inputs, and 4 digital outputs, which allow for versatile connectivity options. Its 16-bit resolution and 1.25 MS/s sampling rate ensure high-precision data capture, while bank isolation preserves signal integrity, and auto-calibration maintains measurement accuracy over time and under varying environmental conditions.
Question 3: What are the characteristics and compatibility features of the National Instruments PXI-6238 Digital Multifunction I/O Module with part number 779624-01?
Answer 3: The National Instruments PXI-6238 Digital Multifunction I/O Module, part number 779624-01, boasts 16 analog inputs with a 16-bit resolution and 1.25 MS/s sampling rate, 2 analog outputs, 6 digital inputs, and 4 digital outputs, featuring bank isolation and auto-calibration for improved signal integrity and accuracy. It has an onboard non-modifiable EEPROM for factory settings and a client modifiable area for self-calibration. This module is
Question 4: What are the features and specifications of the National Instruments PXI-6238 Digital Multifunction I/O Module, and how does its design ensure accuracy and compatibility with a variety of sensors?
Answer 4: The National Instruments PXI-6238 Digital Multifunction I/O Module boasts 16 analog inputs with 16-bit resolution and a 1.25 MS/s sampling rate, 2 analog outputs, 6 digital inputs, and 4 digital outputs, offering versatile interfacing options. It is designed with bank isolation for improved signal integrity and features auto-calibration to maintain measurement accuracy over time and under different environmental conditions. The device’s onboard EEPROM stores calibration constants securely, while also providing a client
Question 5: What are the key features and components that make the National Instruments PXI-6238 Digital Multifunction I/O Module particularly suitable for interfacing with a variety of sensors, and how do these features ensure accurate and precise measurements?
Answer 5: The National Instruments PXI-6238 Digital Multifunction I/O Module boasts 16 analog inputs with 16-bit resolution and a 1.25 MS/s sampling rate, 2 analog outputs, 6 digital inputs, and 4 digital outputs, features bank isolation and auto-calibration, stores calibration constants on a secure onboard EEPROM with a client modifiable area, and is compatible with a diverse array of sensors such as strain gauges, thermocouples, thermistors, encoders