img

PXI-8232

The National Instruments PXI-8232 is a PXI GPIB Instrument Control Module with integrated Gigabit Ethernet, supporting transfer rates up to 1,000 Mbit/s and HS488 speeds up to 7.7 MB/s, featuring automatic

In Stock | Ships Today

img

    Description

    The National Instruments PXI-8232 PXI GPIB Instrument Control Module is a versatile device, accommodating a range of part numbers including 781753-01, 778658-01, 778659-01, and 189140D-02L, each tailored for different operating systems. This module boasts an IEEE 488 and Gigabit Ethernet interface, enhanced by the integration of an Intel 82540EM Gigabit Ethernet controller, ensuring rapid data transfer rates of up to 1,000 Mbit/s, and maintaining compatibility with both 10BASE T and 100BASE TX networks.

    Specific part numbers cater to various operating systems: 781753-01 for Windows and LabVIEW Real-Time, 778658-01 for Windows and LabVIEW Real-Time 2009 and earlier versions, and 778659-01 for legacy systems like Windows NT/ME/96. The module also supports EtherCAT master functionality when used with NI-Industrial Communications for EtherCAT in LabVIEW, and includes a complimentary license for NI 488.2 driver software.

    Connectivity is not an issue, as the module is equipped with a standard RJ-45 ether connector and a standard 24-pin IEEE 488 connector. It is capable of achieving transfer rates up to 7.7 MB/s using HS488 and has the added convenience of automatic cable polarity detection. For even higher speed requirements, the module’s IEEE 488.1 interface allows for transfer rates greater than 1.5 Mbytes/s.

    < Question 1: What are the different operating systems associated with the specific part numbers of the National Instruments PXI-8232 PXI GPIB Instrument Control Module, and what are the data transfer capabilities of its Gigabit Ethernet and IEEE 488 interfaces?
    Answer 1: The National Instruments PXI-8232 PXI GPIB Instrument Control Module has part numbers 781753-01 for Windows and LabVIEW Real-Time, 778658-01 for Windows and LabVIEW Real-Time 2009 and earlier, and 778659-01 for legacy systems such as Windows NT/ME/98, with its Gigabit Ethernet interface capable of data transfer rates up to 1,000 Mbit/s, and its IEEE 488 interface achieving transfer rates greater than

    Question 2: What are the different part numbers of the National Instruments PXI-8232 PXI GPIB Instrument Control Module designed for compatibility with various operating systems, and what additional functionalities does this module offer?
    Answer 2: The National Instruments PXI-8232 PXI GPIB Instrument Control Module features an IEEE 488 and Gigabit Ethernet interface, with an Intel 82540EM Gigabit Ethernet controller enabling data transfer rates up to 1,000 Mbit/s, and is compatible with 10BASE T and 100BASE TX networks. It accommodates different part numbers for compatibility with various operating systems: 781753-01 for Windows and LabVIEW Real-Time, 778658-01 for Windows and

    Question 3: Which specific part number of the National Instruments PXI-8232 PXI GPIB Instrument Control Module is compatible with Windows NT/ME/96 operating systems, and what are the maximum data transfer rates achievable through its IEEE 488 and Gigabit Ethernet interfaces?
    Answer 3: The National Instruments PXI-8232 PXI GPIB Instrument Control Module includes part numbers 781753-01 for Windows and LabVIEW Real-Time, 778658-01 for Windows and LabVIEW Real-Time 2009 and earlier, and 778659-01 for legacy systems like Windows NT/ME/96; it offers additional functionalities such as Gigabit Ethernet interface, Intel 82540EM Gigabit Ethernet controller for high-speed data transfer, compatibility with 10BASE-T and

    Question 4: What specific part numbers of the National Instruments PXI-8232 PXI GPIB Instrument Control Module are designed for different operating systems and what additional functionalities does this module support?
    Answer 4: The specific part number of the National Instruments PXI-8232 PXI GPIB Instrument Control Module that is compatible with Windows NT/ME/96 operating systems is 778659-01, and the maximum data transfer rates achievable through its IEEE 488 and Gigabit Ethernet interfaces are 7.7 MB/s and 1,000 Mbit/s, respectively.

    Question 5: What are the capabilities and features of the National Instruments PXI-8232 PXI GPIB Instrument Control Module, including its compatibility with various operating systems and network types?
    Answer 5: The National Instruments PXI-8232 PXI GPIB Instrument Control Module includes part numbers 781753-01 for Windows and LabVIEW Real-Time, 778658-01 for Windows and LabVIEW Real-Time 2009 and earlier, and 778659-01 for legacy systems such as Windows NT/ME/98, and it supports additional functionalities like EtherCAT master functionality with NI-Industrial Communications for EtherCAT in LabVIEW, as well as a complimentary license for NI 488.

    Feature Specification
    Product Name National Instruments PXI-8232 PXI GPIB Instrument Control Module
    Part Numbers 781753-01, 778658-01, 778659-01, 189140D-02L
    Interface IEEE 488, Gigabit Ethernet
    Integrated Controller 82540EM Gigabit Ethernet controller from Intel
    Ethernet Transfer Rate Up to 1,000 Mbit/s (compatible with 10BASE T and 100BASE TX)
    Compatible Operating Systems for Part Numbers 781753-01 (Windows, LV RT), 778658-01 (Windows, LV RT 2009 and prior), 778659-01 (Windows NT/ME/96)
    EtherCAT Master Support Yes, with NI-Industrial Communications for EtherCAT in LabVIEW
    Software License Included NI 488.2 driver software
    Connectors Standard RJ-45 ether connector, Standard 24-pin IEEE 488 connector
    HS488 Transfer Rates Up to 7.7 MB/s
    Automatic Cable Polarity Detection Yes
    IEEE 488.1 Transfer Rate Higher than 1.5 Mbytes/s