img

PXI-8460-1

The National Instruments PXI-8460/1 PXI-CAN Interface (Part Number: 778008-01) is a low-speed, single-port CAN interface with a Philips SJA1000 controller, featuring advanced functionalities like listen-only mode

In Stock | Ships Today

img

    Description

    The National Instruments PXI-8460/1 PXI-CAN Interface, with part number 778008-01, is a specialized network interface that employs a Controller Area Network (CAN) interface type. This single-port interface supports low-speed communication with speeds of up to 125 kb/s, making it suitable for various applications.

    Utilizing the Philips SJA1000 CAN controller, it offers multiple features such as listen only, echo, advanced filtering, and a rest/wakeup mode. The interface comes with NI-CAN device programming software, streamlining the development process.

    Significantly, it can be synchronized using the PXI trigger bus, which allows it to integrate seamlessly with CAN, DAQ, vision, and motion modules. This makes it ideal for complex systems requiring tight coordination between different types of measurements.

    It is also compatible with LabVIEW Real-Time, ensuring deterministic control in real-time applications and conformity to the stringent standards required for CAN vehicle systems. Additionally, its ability to share timing and triggering signals with other measurement devices enhances its integration capabilities.

    The determinism of the system is guaranteed through hardware-handled timing and triggering signals, ensuring reliable and accurate performance in demanding environments.

    Attribute Description
    Product Name National Instruments PXI-8460/1 PXI-CAN Interface
    Part Number 778008-01
    Interface Type Controller Area Network (CAN)
    Number of Ports 1-port
    Speed Low-speed, up to 125 kb/s
    CAN Controller Philips SJA1000
    Special Features Listen only, Echo, Advanced filtering, Rest/Wakeup mode
    Software NI-CAN device programming software
    Synchronization Utilizes PXI trigger bus for synchronization with CAN, DAQ, vision, and motion modules
    Real-Time Support Compatible with LabVIEW Real-Time
    Standards Compliance Meets physical and electrical requirements for CAN vehicle systems
    Integration Capability Can share timing and triggering signals with other measurement devices
    Determinism Maintained via hardware-handled timing and triggering signals

    Question 1: What are the key features and benefits of the National Instruments PXI-8460/1 PXI-CAN Interface with part number 778008-01, and how does it ensure reliable performance in real-time applications?
    Answer 1: The Philips SJA1000 CAN controller on the National Instruments PXI-8460/1 PXI-CAN Interface provides features such as listen only mode, echo, advanced filtering, and a rest/wakeup mode.

    Question 2: What are the key features and capabilities of the National Instruments PXI-8460/1 PXI-CAN Interface, part number 778008-01, and how does it ensure reliable performance in synchronized systems and real-time applications?
    Answer 2: The National Instruments PXI-8460/1 PXI-CAN Interface with part number 778008-01 is equipped with a Controller Area Network (CAN) interface supporting up to 125 kb/s, utilizes the Philips SJA1000 CAN controller for features like listen only, echo, advanced filtering, and rest/wakeup mode, and comes with NI-CAN software for streamlined development. It can be synchronized via the PXI trigger bus for integration with various modules, is compatible with LabVIEW

    Question 3: What functionality does the National Instruments PXI-8460/1 PXI-CAN Interface with part number 778008-01 provide for systems that require synchronized measurements and deterministic control using the CAN interface?
    Answer 3: The National Instruments PXI-8460/1 PXI-CAN Interface with part number 778008-01 provides synchronized measurements and deterministic control for systems using the CAN interface by offering features like listen-only mode, echo, advanced filtering, rest/wakeup mode, and the ability to integrate with other modules via the PXI trigger bus, while also being compatible with LabVIEW Real-Time for real-time applications.

    Question 4: Which features are provided by the Philips SJA1000 CAN controller on the National Instruments PXI-8460/1 PXI-CAN Interface?
    Answer 4: The National Instruments PXI-8460/1 PXI-CAN Interface, part number 778008-01, features a Controller Area Network (CAN) interface with up to 125 kb/s communication speed, a Philips SJA1000 CAN controller with capabilities like listen-only mode, echo, advanced filtering, and rest/wakeup mode. It includes NI-CAN software for easier programming, can synchronize with the PXI trigger bus for coordination with various modules, is compatible with LabVIEW Real-Time

    Question 5: What communication speeds and specialized features does the National Instruments PXI-8460/1 PXI-CAN Interface support, and how does it ensure deterministic performance in real-time applications?
    Answer 5: The National Instruments PXI-8460/1 PXI-CAN Interface supports low-speed communication with speeds of up to 125 kb/s and offers specialized features such as listen only, echo, advanced filtering, and a rest/wakeup mode; it ensures deterministic performance in real-time applications by being compatible with LabVIEW Real-Time and through hardware-handled timing and triggering signals for reliable and accurate operation.