Description
The NI SC-2345 Shielded Carrier is identified by a variety of part numbers, including 777458-01, 777458-02, 777458-03, 777722-01, 777722-02, 777722-03, 778018-01, 778018-02, and 778018-03. This model, known as the SC-2345, is designed to offer exceptional performance for signal conditioning applications.
The SC-2345 stands out due to its low-noise, rugged build, and user-friendly features. It provides separate signal conditioning for each channel, ensuring precise and reliable data capture. The carrier includes 42 screw terminals, 8 digital I/O 20-pin connectors, and 16 analog I/O 20-pin connectors, making it versatile for a wide range of applications.
For software compatibility, the SC-2345 works seamlessly with NIDAQ driver software (version 7.4 or later), LabVIEW, and LabWindows/CVI. It also supports configuration through the Measurement & Automation Explorer (MAX), enhancing its ease of use.
This shielded carrier is compatible with both analog I/O and digital I/O SCC modules, making it highly adaptable for different signal processing needs. It features an onboard output voltage reference of 5 V ± 2.5 mV, ensuring accurate signal conversion. The SC-2345 boasts long-term stability of ±15 ppm per 1000 hours, and its peak-to-peak value is measured at four micro-volts, highlighting its precision and reliability over time.
The SC-2345 is also designed with practicality in mind, weighing in at 1.51 kilograms and measuring 10.00 x 12.11 x 1.93 inches (W x L x D). These dimensions make it a compact and manageable solution for a variety of setups. Whether used in a laboratory, industrial setting, or for educational purposes, the NI SC-2345 Shielded Carrier delivers outstanding performance and adapt
| Specification | Details |
|---|---|
| Part Numbers | 777458-01, 777458-02, 777458-03, 777722-01, 777722-02, 777722-03, 778018-01, 778018-02, 778018-03 |
| Model | SC-2345 |
| Description | NI SC-2345 Shielded Carrier |
| Features | Low-noise, rugged build, easy to use signal conditioning, separate signal conditioning for each channel, 42 screw terminals, 8 digital I/O 20-pin connectors, 16 analog I/O 20-pin connectors |
| Software Compatibility | NIDAQ driver software (version 7.4 or later), LabVIEW, LabWindows/CVI |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Supported Modules | Analog I/O and digital I/O SCC modules |
| Onboard Output Voltage Reference | 5 V ± 2.5 mV |
| Long-term Stability | ±15 ppm per 1000 hours |
| Peak-to-Peak Value | Four micro-volts |
| Weight | 1.51 kilograms |
| Dimensions (W x L x D) | 10.00 x 12.11 x 1.93 inches | Question 1: What is the weight of the NI SC-2345?