img

PXIe-2727

The National Instruments PXIe-2727 PXI Programmable Resistor Module, part number 781986-27, is a 9-channel, 16-bit module capable of outputting up to 16 kiloohm with a minimum

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-2727 PXI Programmable Resistor Module, with part number 781986-27, is a high-precision, 9-channel, 16-bit resistor module designed for diverse applications, capable of delivering a maximum resistance output of 16 kiloohm with a minimum step size of 0.25 ohm.

    Channel accuracy varies based on resistance settings, offering less than 5.0% accuracy for resistance between 20 Ω and 64 Ω, less than 2.0% for 64 Ω to 255 Ω, and even higher precision as the resistance increases, with less than 1.0% accuracy for 400 Ω to 16,000 Ω.

    Each channel can handle up to 0.3 A of current and has a maximum power rating of 0.25 W, making it an essential tool for simulating and testing resistance-based sensors and circuits in a controlled laboratory environment.

    Specification Detail
    Manufacturer National Instruments
    Product Name PXIe-2727 PXI Programmable Resistor Module
    Part Number 781986-27
    Channels 9-channel, 16-bit
    Maximum Resistance Output 16 kiloohm
    Minimum Step Size 0.25 ohm
    Channel Accuracy (20 Ω to 64 Ω) <5.0%
    Channel Accuracy (64 Ω to 255 Ω) <2.0%
    Channel Accuracy (20 Ω to 40 Ω) <10.0%
    Channel Accuracy (40 Ω to 120 Ω) <5.0%
    Channel Accuracy (120 Ω to 400 Ω) <2.0%
    Channel Accuracy (400 Ω to 16,000 Ω) <1.0%
    Maximum Current per Channel 0.3 A
    Maximum Power per Channel 0.25 WQuestion 1: What is the accuracy of the National Instruments PXIe-2727 PXI Programmable Resistor Module when set between 64 ohms and 255 ohms?
    Answer 1: The National Instruments PXIe-2727 PXI Programmable Resistor Module offers accuracy specifications of less than 5.0% for resistances between 20 ohms and 64 ohms, less than 2.0% for resistances from 64 ohms to 255 ohms, and even higher precision with less than 1.0% accuracy for resistances ranging from 400 ohms to 16,000 ohms.

    Question 2: What are the accuracy specifications of the National Instruments PXIe-2727 PXI Programmable Resistor Module for different resistance ranges?
    Answer 2: The accuracy range of the National Instruments PXIe-2727 PXI Programmable Resistor Module for resistance settings between 64 ohms and 255 ohms is less than 2.0%.

    Question 3: What is the accuracy range of the National Instruments PXIe-2727 PXI Programmable Resistor Module for resistance settings between 64 ohms and 255 ohms?
    Answer 3: The National Instruments PXIe-2727 PXI Programmable Resistor Module offers resistance accuracy ranging from less than 5.0% for resistance between 20 ohms and 64 ohms, less than 2.0% for 64 ohms to 255 ohms, and less than 1.0% for 400 ohms to 16,000 ohms.

    Question 4: What is the range of resistance accuracy that the National Instruments PXIe-2727 PXI Programmable Resistor Module provides for resistance settings between 20 ohms and 16,000 ohms?
    Answer 4: The accuracy of the National Instruments PXIe-2727 PXI Programmable Resistor Module when set between 64 ohms and 255 ohms is less than 2.0%.

    Question 5: What is the channel accuracy for the National Instruments PXIe-2727 PXI Programmable Resistor Module when set to resistance values between 64 ohms and 255 ohms?
    Answer 5: The channel accuracy for the National Instruments PXIe-2727 PXI Programmable Resistor Module when set to resistance values between 64 ohms and 255 ohms is less than 2.0%.