Description
The SC-2345 is a Shielded Carrier model, meticulously designed by National Instruments, renowned for its innovation in the field. This carrier is specifically tailored to support 68-pin E/M DAQ devices, ensuring a broad compatibility range for various data acquisition tasks. It stands out with its low-noise performance and rugged build, making it an excellent choice for demanding environments where data integrity and durability are paramount.
The SC-2345 boasts an impressive array of 42 screw terminals, facilitating easy and secure connections. Additionally, it is equipped with 8 20-pin digital I/O connectors and 16 20-pin analog I/O connectors, offering ample connectivity options for a wide range of sensors and actuators. The carrier is designed for use with NIDAQ version 7.4 or later, ensuring seamless integration with up-to-date driver software.
Compatibility with popular software such as LabVIEW and LabWindows/CVI is ensured, allowing for a flexible and user-friendly development environment. The SC-2345 also supports configuration through the Measurement & Automation Explorer (MAX), providing an intuitive tool for setup and management. It is designed to work with both analog I/O and digital I/O SCC modules, providing a versatile platform for a variety of data acquisition applications.
Furthermore, the SC-2345 features an onboard output voltage reference of 5 V ± 2.5 mV, ensuring precise measurements and reliable operation. Its part numbers include 777458-01, 777458-02, 777458-03, 777722-01, 777722-02, 777722-03, 778018-01, 778018-02, and 778018-03, covering a range of options to meet specific requirements. With its easy-to-use signal conditioning, which is separate for each channel, the SC-2345 stands as a top-tier choice for professionals seeking a high-quality, reliable solution for their data acquisition needs.
| Specification | Details |
|---|---|
| Model | SC-2345 |
| Part Numbers | 777458-01, 777458-02, 777458-03, 777722-01, 777722-02, 777722-03, 778018-01, 778018-02, 778018-03 |
| Type | Shielded Carrier |
| Manufacturer | National Instruments |
| Compatibility | 68-pin E/M DAQ devices |
| Features | Low-noise, rugged build, easy to use signal conditioning, separate for each channel |
| Screw Terminals | 42 |
| Digital I/O Connectors | 8 20-pin connectors |
| Analog I/O Connectors | 16 20-pin connectors |
| Driver Software | NIDAQ version 7.4 or later |
| Compatible Software | LabVIEW, LabWindows/CVI |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Supported Modules | Analog I/O and digital I/O SCC modules |
| Onboard Output Voltage Reference | 5 V ± 2.5 mV |


