Description
The SCXI-1000, a chassis designed for SCXI modules, comes with an array of part numbers including 776570-01, 776570-02, 776570-03, 776570-04, 776570-05, 776570-06, 776570-07, 778570-01, 778570-04, 776570-09, and 776570-10. This product is capable of supporting a maximum of 8 chassis per system, providing flexibility in system configuration.
It is designed to operate across various line voltages, namely 100, 120, 220, and 240 VAC, ensuring compatibility with global electrical standards. Each slot within the chassis has a power dissipation rate of 7 W, allowing for efficient management of module power requirements.
The operating temperature range for the SCXI-1000 is between 0 to 50 °C, and it can be stored in temperatures ranging from –20 to 70 °C, ensuring reliability across a wide range of environmental conditions. The chassis boasts physical dimensions of 9.8 x 7.7 x 7.0 inches and weighs 10 oz, making it compact and lightweight for easy integration into various setups.
Despite its obsolete status, as announced by National Instruments, the SCXI-1000 remains available for purchase and repair through Apex Waves. This ensures that users can continue to utilize this essential component in their test, measurement, and automation applications. Furthermore, the chassis supports 32 different addresses, providing ample configuration options for complex systems.
| Specification | Detail |
|---|---|
| Part Numbers | 776570-01, 776570-02, 776570-03, 776570-04, 776570-05, 776570-06, 776570-07, 778570-01, 778570-04, 776570-09, 776570-10 |
| Model | SCXI-1000 |
| Type | Chassis for SCXI Modules |
| Max Number of Chassis per System | 8 |
| Line Voltages | 100, 120, 220, 240 VAC |
| Power Dissipation | 7 W per slot |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –20 to 70 °C |
| Physical Dimensions | 9.8 x 7.7 x 7.0 in |
| Weight | 10 oz |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves |
| Address Configurations | 32 different addresses |
Question 1: What is the operating temperature range of SCXI-1000?
Answer 1: 0 to 50 °C
Question 2: How many chassis per system does SCXI-1000 support?
Answer 2: Up to 8
Question 3: What is the power dissipation rate per slot in SCXI-1000?
Answer 3: 7 W
Question 4: Is the SCXI-1000 available for purchase or repair?
Answer 4: Yes, available through Apex Waves
Question 5: What are the physical dimensions of the SCXI-1000?
Answer 5: 9.8 x 7.7 x 7.0 inches