Description
The SCXI-1102 is part of the SCXI & Legacy category and is identified by part numbers 183084L-01L, 776572-02, 183087H-01. This model features 32-Channel Voltage Input capabilities, making it suitable for a wide range of measurement and testing applications. Each channel is equipped with 2 Hz lowpass filtering, ensuring clean signal processing and reducing the likelihood of high-frequency noise interference.
One of the key features of the SCXI-1102 is its overvoltage protection, which can handle up to ±42 V, safeguarding the device against unexpected voltage spikes. The bandwidth is also rated at 2 Hz, aligning with the lowpass filtering capabilities to deliver accurate and reliable data.
The model boasts a maximum sampling rate of 333 kS/s, high enough for most voltage input applications. It is designed to accommodate a variety of input signals, including Millivolt, Volt, 0 to 20 mA, and 4 to 20 mA, providing versatility in its use across different types of sensors and signal sources.
Compatibility is a significant advantage of the SCXI-1102, as it works seamlessly with a range of accessories and modules such as SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96. For those looking to perform precise thermocouple measurements, the recommended terminal block is the SCXI-1303.
To get started with the SCXI-1102, several required items are listed, including an SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, a computer (for SCXI chassis), cabling, a cable adapter, and sensors. Additionally, the SCXI-1102 is compatible with software like NI-DAQmx, LabVIEW
| Specification | Details |
|---|---|
| Part Number | 183084L-01L, 776572-02, 183087H-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1102 |
| Channels | 32-Channel Voltage Input |
| Lowpass Filtering | 2 Hz for each channel |
| Overvoltage Protection | ±42 V |
| Bandwidth | 2 Hz |
| Maximum Sampling Rate | 333 kS/s |
| Input Signals | Millivolt, Volt, 0 to 20 mA, 4 to 20 mA |
| Compatibility | SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96 |
| Recommended Terminal Block | SCXI-1303 for precise thermocouple measurements |
| Required Items | SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, computer (for SCXI chassis), cabling, cable adapter, sensors |
| Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI,
Question 1: What is the part number for SCXI-1102? Question 2: How many channels does SCXI-1102 have? Question 3: What is SCXI-1102’s max sampling rate? Question 4: Does SCXI-1102 have overvoltage protection? Question 5: What software is SCXI-1102 compatible with? |