Description
The National Instruments SCXI-1102 Voltage Input Module, with part numbers 183087J-01, 776572-02, 183087H-01, falls within the SCXI & Legacy category. This model, SCXI-1102, is designed to cater to a broad spectrum of applications requiring voltage input.
It boasts a 32-Channel Voltage Input, making it versatile for various testing and measurement scenarios. The module is packed with features including hardware scanning of cold-junction sensors, overvoltage protection up to ±42 V, 2 Hz lowpass filtering per channel, and a maximum sampling rate of 333 kS/s, ensuring accurate and reliable data acquisition.
The bandwidth of the SCXI-1102 is set at 2 Hz, which is suitable for capturing high-quality data across a range of signal types. It is compatible with millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals, as well as RTDs (with SCXI-1581), allowing for flexibility in the types of measurements it can perform.
For connectivity, the module is compatible with several terminal blocks, including SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, and TBX-96, providing users with a variety of options for connecting their sensors and other devices.
When setting up a system, the recommended accessories for the SCXI-1102 include an SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, a computer (if using an SCXI chassis), cabling, a cable adapter, and sensors. These components are essential for a complete and functional setup.
Lastly, the SCXI-1102 is compatible with several software platforms, including NI-DAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio. This compatibility ensures that users can integrate the module seamlessly into their existing systems and workflows, leveraging powerful software tools for data analysis and visualization.
| Specification | Detail |
|---|---|
| Part Number | 183087J-01, 776572-02, 183087H-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1102 |
| Description | National Instruments SCXI-1102 Voltage Input Module |
| Channels | 32-Channel Voltage Input |
| Features | Hardware scanning of cold-junction sensors, Overvoltage protection to ±42 V, 2 Hz lowpass filtering per channel, 333 kS/s maximum sampling rate |
| Bandwidth | 2 Hz |
| Signal Compatibility | Millivolt, Volt, 0 to 20 mA, and 4 to 20 mA current input signals, RTDs (with SCXI-1581) |
| Compatible Terminal Blocks | SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310, TC-2095, TBX-1303, TBX-96 |
| Recommended Accessories | SCXI chassis or PXI/SCXI combination chassis, SCXI-1600 or E/M Series DAQ Device, Computer (if using an SCXI chassis), Cabling, Cable adapter, Sensors |
| Software Compatibility | NI-DAQmx, LabVIEW, LabWindows/CVI, Measurement Studio |
| Connect
Question 1: What is the max sampling rate of SCXI-1102? Question 2: How many voltage input channels does SCXI-1102 have? Question 3: What type of protection does SCXI-1102 offer? Question 4: What type of filtering does each channel of SCXI-1102 have? Question 5: Is the SCXI-1102 compatible with LabVIEW software? |