Description
The SCXI-1104 is a specialized module, designed to handle the signal conditioning of high voltage signals. Its part number is 183087-04 (776572-04), categorizing it under SCXI & Legacy products. This module is adept at managing signal types up to 30 VACrms, ±42 VACpeak, ±60 VDC, making it an essential tool for high voltage signal applications.
One of the SCXI-1104’s key features is its three-pole lowpass filter, which has a 2 Hz cutoff frequency. This filter ensures that the signal is clean and free of high-frequency noise, which is crucial for accurate measurements and analysis. However, it is important to note that this module does not support ribbon-cabled multichassis SCXI systems. For multichassis setups, the SCXI-1346 is required.
The SCXI-1104 utilizes the SCXIbus interface for communication, providing a robust and reliable connection. It also supports indirect scanning, which can be enabled via a switch on the module. This feature allows for greater versatility in signal acquisition and monitoring.
For connectivity, the SCXI-1104 requires specific devices, including the SCXI-1310, TBX-96, BNC-2095, and SCXI-1300. These devices ensure that the module can be effectively integrated into various setups, providing flexibility in its application. Software compatibility is broad, with requirements including VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW. Additionally, device drivers such as NI-DAQ for Macintosh or PC Compatibles are necessary for operation.
The module is equipped with a 50-pin male ribbon cable back connector and a 96-pin male DIN C front connector, facilitating easy and secure connections. Its dimensions are 4.54 x 10.75 inches, making it a compact solution that can fit into various setups without requiring excessive space. Lastly, the SCXI-1104 operates within a temperature range
| Feature | Description |
|---|---|
| Part Number | 183087-04 (776572-04) |
| Category | SCXI & Legacy |
| Model | SCXI-1104 |
| Application | Signal conditioning of high voltage signals |
| Signal Types | 30 VACrms, ±42 VACpeak, ±60 VDC |
| Filter | Three-pole lowpass filter with a 2 Hz cutoff frequency |
| Compatibility | Does not support ribbon-cabled multichassis SCXI systems; Requires SCXI-1346 for multichassis setups |
| Interface | SCXIbus |
| Indirect Scanning | Supported via switch on module |
| Connectivity Devices (Required) | SCXI-1310, TBX-96, BNC-2095, SCXI-1300 |
| Software Requirements | VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW |
| Device Drivers | NI-DAQ for Macintosh or PC Compatibles |
| Connectors | 50-pin male ribbon cable back connector, 96-pin male DIN C front connector |
| Dimensions | 4.54 x 10.75 in. |
| Operating Temperature Range | 0 to 50 °C |