<p>The <strong>National Instruments SCXI-1104 Voltage Input Module</strong> is a distinguished component within the SCXI & Legacy category, identified by its part number <strong>183087H-06 (776572-04)</strong>. This module is meticulously designed for signal conditioning of <strong>medium-voltage signals</strong>, accommodating <strong>30 VACrms, ±42 VACpeak, ±60 VDC</strong> inputs. It integrates a <strong>three-pole lowpass filter</strong> with a <strong>2 Hz cutoff frequency</strong>, optimizing the signal processing capabilities.</p><p>Compatibility with <strong>SCXIbus</strong> is affirmed, ensuring seamless integration with related systems. However, it is noteworthy that this module does <strong>not support</strong> ribbon-cabled multichassis SCXI systems, which may influence system design considerations. To enhance functionality, specific <strong>connectivity devices</strong> are necessary, including <strong>SCXI-1310, TBX-96, BNC-2095, and SCXI-1300</strong>.</p>
<p>For software interfacing, the module requires the installation of certain <strong>software packages</strong>, notably <strong>VirtualBench, ComponentWorks, Measure, LabWindows/CVI, and LabVIEW</strong>. Device drivers such as <strong>NI-DAQ for Macintosh or PC Compatibles</strong> are essential for the operation of this module, facilitating its integration with computing platforms.</p>
<p>The physical dimensions of the SCXI-1104 are <strong>4.54 x 10.75 inches</strong>, making it a compact yet potent component suitable for various applications. It operates effectively within a temperature range of <strong>0 to 50 °C</strong> and can be stored in conditions ranging from <strong>–55 to 85 °C
| Specification | Detail |
|---|---|
| Part Number | 183087H-06 (776572-04) |
| Category | SCXI & Legacy |
| Model | SCXI-1104 |
| Description | National Instruments SCXI-1104 Voltage Input Module |
| Signal Conditioning | Medium-voltage signals: 30 VACrms, ±42 VACpeak, ±60 VDC |
| Lowpass Filter | Three-pole, 2 Hz cutoff frequency |
| SCXIbus Compatibility | Yes |
| Support for Ribbon-Cabled Multichassis SCXI Systems | No |
| Connectivity Devices (Necessary) | SCXI-1310, TBX-96, BNC-2095, SCXI-1300 |
| Software Packages (Necessary) | VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW |
| Device Drivers | NI-DAQ for Macintosh or PC Compatibles |
| Physical Dimensions | 4.54 x 10.75 in. |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –55 to
Question 1: What is the part number for the SCXI-1104? Question 2: What type of signals does the SCXI-1104 process? Question 3: Does the SCXI-1104 support multichassis SCXI systems? Question 4: What is the cutoff frequency of the SCXI-1104's lowpass filter? Question 5: What software is required for the SCXI-1104 module? |