Description
The product with the part number 776572-04 falls under the category of SCXI & Legacy. It is specifically the model SCXI-1104, which is described as a 32-Channel 42-Volt Multiplexer. This device is particularly suitable for the signal conditioning of high voltage signals. The supported voltage signals for this multiplexer are 30 VACrms, ±42 VACpeak, ±60 VDC.
It features a lowpass filter with a cutoff frequency of 2 Hz and includes an SCXIbus Interface. For those looking to utilize multichassis setups, this can be achieved with the use of an SCXI-1346 adapter. In terms of connectivity, this device requires one of the following connectivity devices: SCXI-1310, TBX-96, BNC-2095, or SCXI-1300.
When it comes to software compatibility, this multiplexer works with VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW. Moreover, it is compatible with device drivers such as NI-DAQ for Macintosh or NI-DAQ for PC Compatibles. The connectors included are a 50-pin male ribbon cable back connector, and a 96-pin male DIN C front connector.
The physical dimensions of the device are 4.54 x 10.75 in., and it operates within a temperature range of 0 to 50 °C. The storage temperature range is quite wide, from –55 to 150 °C, and it can function in relative humidity ranging from 5% to 90% (non-condensing). It is important to note that this device has an obsolete status, as announced by National Instruments; however, it remains available for purchase and repairs through Apex Waves.
| Specification | Detail |
|---|---|
| Part Number | 776572-04 |
| Category | SCXI & Legacy |
| Model | SCXI-1104 |
| Description | 32-Channel 42-Volt Multiplexer |
| Suitable For | Signal conditioning of high voltage signals |
| Supported Voltage Signals | 30 VACrms, ±42 VACpeak, ±60 VDC |
| Lowpass Filter Cutoff Frequency | 2 Hz |
| SCXIbus Interface | Yes |
| Multichassis Support | With SCXI-1346 adapter |
| Required Connectivity Device | SCXI-1310, TBX-96, BNC-2095, or SCXI-1300 |
| Software Compatibility | VirtualBench, ComponentWorks, Measure, LabWindows/CVI, LabVIEW |
| Device Driver Compatibility | NI-DAQ for Macintosh or NI-DAQ for PC Compatibles |
| Connectors | 50-pin male ribbon cable back connector, 96-pin male DIN C front connector |
| Physical Dimensions | 4.54 x 10.75 in. |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –55 to 150 °C |
| Relative Humidity Range | 5% to 90% (non-condensing) |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves
Question 1: What is the part number of the SCXI-1104? Answer 1: 776572-04 Question 2: How many channels does the SCXI-1104 support? Question 3: What is the maximum DC voltage the SCXI-1104 can handle? Question 4: What adapter is needed for multichassis support in SCXI-1104? Question 5: Is the SCXI-1104 considered obsolete? |