The SCXI-1104C falls under the SCXI & Legacy category, showcasing its specialized design for legacy systems. This model is equipped with a 32 channel, 42 V multiplexer, optimized for differential inputs. Its part numbers include 183087K-05L, 776572-04C, and 183087H-05, indicating the various iterations and versions available within this model line.
It boasts a cut-off frequency of 10 kHz, ensuring that it can handle signals up to this frequency effectively. For systems that require expansion across multiple chassis, the SCXI-1346 adapter is required, ensuring seamless integration and functionality.
While the SCXI-1104C does not offer analog output overvoltage protection, it does provide short-circuit protection on its analog outputs, enhancing its durability and reliability in demanding environments. The warm-up time for this device is approximately 20 minutes, after which it operates optimally within a temperature range of 0 to 50 °C.
Calibration of the SCXI-1104C is recommended annually or as needed to maintain accuracy and performance. It is compatible with NI-DAQ version 6.5.1 or higher, ensuring that it can be integrated with modern software drivers for data acquisition and control. Connectivity is facilitated through a 50-pin male ribbon cable (back) and a 96-pin male DIN C (front), providing versatile options for physical integration into systems.
The obsolete status of the SCXI-1104C has been announced, indicating that it is transitioning out of active production but still supports users through Calibration Availability. Calibration services are available through Apex Waves, offering both NIST accredited or basic options to meet various standards and requirements.
| Specification | Detail |
|---|---|
| Part Number | 183087K-05L, 776572-04C, 183087H-05 |
| Category | SCXI & Legacy |
| Model | SCXI-1104C |
| Description | 32 ch, 42 V Multiplexer |
| Channels | 32 differential |
| Cut-off Frequency | 10 kHz |
| Required Adapter for Multichassis System | SCXI-1346 |
| Analog Output Overvoltage Protection | No |
| Analog Outputs Short-circuit Protection | Yes |
| Warm-up Time | 20 minutes |
| Operating Temperature | 0 to 50 °C |
| Calibration Frequency | Annually or as needed |
| Software Driver | NI-DAQ version 6.5.1 or higher |
| Connectors | 50-pin male ribbon cable (back), 96-pin male DIN C (front) |
| Obsolete Status | Announced |
| Calibration Availability | Yes, through Apex Waves with NIST accredited or basic options |
Question 1: What is the cutoff frequency of SCXI-1104C?
Answer 1: 10 kHz
Question 2: Does SCXI-1104C provide short-circuit protection?
Answer 2: Yes, on its analog outputs.
Question 3: What is the warm-up time for SCXI-1104C?
Answer 3: Approximately 20 minutes.
Question 4: Is calibration for SCXI-1104C recommended annually?
Answer 4: Yes, annually or as needed.
Question 5: What versions of NI-DAQ is SCXI-1104C compatible with?
Answer 5: Version 6.5.1 or higher.