img

185959F-01

The SCXI-1125 is an 8-channel programmable isolated input module with 300 Vrms isolation and supports various input types, requiring NI-DAQmx 9.0 or later.

In Stock | Ships Today

img

    Description

    The Part Number for this product is 185959F-01 (776872-25), categorizing it under SCXI & Legacy with the model name SCXI-1125. This model is described as a 8 ch Programmable Isolated Input Module, designed to handle a variety of inputs with a 300 Vrms working isolation for safety and reliability. It has 8 input channels that can accommodate millivolt sources, volt sources, 0 to 20 mA, 4 to 20 mA, and thermocouples, making it highly versatile.

    The output range of this module is ±5.0 V, and it features automatic low pass filtering that can be configured for either 4 Hz or 10 kHz, depending on the needs of the application. For ease of use and precision, it includes programmable offset calibration with onboard EEPROM for storage. This ensures that the module can be accurately calibrated without the need for external tools or software.

    It has a weight of 22.6 oz and dimensions of 7.4 x 6.8 x 1.2 in, making it compact enough for use in a variety of settings without sacrificing performance. For software compatibility, it requires NI-DAQmx 9.0 or later, and is compatible with LabVIEW, LabWindows/CVI, and Measurement Studio as Application Development Environments (ADEs), providing flexibility in how it can be integrated into systems.

    Question 1: What is the part number for the SCXI-1125?
    Answer 1: 185959F-01 (776872-25)

    Question 2: How many input channels does SCXI-1125 have?
    Answer 2: 8 channels

    Question 3: What is the working isolation voltage for SCXI-1125?
    Answer 3: 300 Vrms

    Question 4: What is the minimum NI-DAQmx version for SCXI-1125?
    Answer 4: NI-DAQmx 9.0 or later

    Question 5: Can SCXI-1125 handle thermocouple inputs?
    Answer 5: Yes

    Specification Detail
    Part Number 185959F-01 (776872-25)
    Category SCXI & Legacy
    Model SCXI-1125
    Description 8 ch Programmable Isolated Input Module
    Isolation 300 Vrms working isolation
    Input Channels 8
    Input Types Millivolt sources, volt sources, 0 to 20 mA, 4 to 20 mA, thermocouples
    Output Range ±5.0 V
    Filtering Automatic low pass filter configurable for 4 Hz or 10 kHz
    Calibration Programmable offset calibration with onboard EEPROM for storage
    Weight 22.6 oz
    Dimensions 7.4 x 6.8 x 1.2 in
    Software Requirement NI-DAQmx 9.0 or later
    Compatible ADEs LabVIEW, LabWindows/CVI, Measurement Studio
    End of Life Status