Description
The National Instruments PXIe-5603 RF Signal Downconverter Module, with part numbers 781429-01 and 781429-02, is designed to convert RF frequencies to lower levels for efficient digitization, featuring a maximum center frequency capability of up to 3.6 GHz. Available in two versions, one without a pre-amp and another with a pre-amp (781429-02), this module ensures versatility for various applications.
It utilizes an SMA female connector and supports both AC and DC coupling, with a maximum DC input voltage of ±25 VDC and a maximum IF output level of +22 dBm. The resolution and temperature stability of the PXIe-5603 are guaranteed to be not less than those of the NI PXIe 5622, ensuring reliable performance.
The device requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power and can handle a LO IN maximum safe voltage of 25 VDC, with a LO OUT maximum safe voltage of 0 VDC. Weighing 32.0 oz, the PXIe-5603 is a robust component suitable for a range of signal processing tasks.
Question 1: What is the difference in functionality between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, specifically part numbers 781429-01 and 781429-02?
Answer 1: The difference between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, part numbers 781429-01 and 781429-02, is that the 781429-02 version includes a pre-amp, which enhances its ability to amplify weak signals, whereas the 781429-01 version does not have this feature.
Question 2: What are the key features and specifications of the National Instruments PXIe-5603 RF Signal Downconverter Module, including its part numbers, frequency capability, and power requirements?
Answer 2: The National Instruments PXIe-5603 RF Signal Downconverter Module requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power, and it ensures reliable performance with a resolution and temperature stability that are guaranteed to be not less than those of the NI PXIe 5622.
Question 3: What are the key features and specifications of the National Instruments PXIe-5603 RF Signal Downconverter Module, including its center frequency capability, available versions with and without a pre-amp, and power requirements?
Answer 3: The National Instruments PXIe-5603 RF Signal Downconverter Module features a maximum center frequency capability of 3.6 GHz, is offered in two versions with part numbers 781429-01 without a pre-amp and 781429-02 with a pre-amp, utilizes an SMA female connector, supports AC and DC coupling, and requires 1.7 A at +3.3 VDC and 1.8 A at +12 VDC for power.
Question 4: What are the differences between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module, specifically part numbers 781429-01 and 781429-02?
Answer 4: The National Instruments PXIe-5603 RF Signal Downconverter Module, with part numbers 781429-01 and 781429-02, features a maximum center frequency capability of up to 3.6 GHz and comes in two versions, one with a pre-amp (781429-02) and one without. It supports AC and DC coupling, uses an SMA female connector, and can handle a maximum DC input voltage of ±25 VDC and a maximum IF output level of +
Question 5: What are the power requirements for the National Instruments PXIe-5603 RF Signal Downconverter Module, and how does it ensure reliable performance in terms of resolution and temperature stability compared to the NI PXIe 5622?
Answer 5: The primary difference between the two versions of the National Instruments PXIe-5603 RF Signal Downconverter Module is that part number 781429-02 includes a pre-amp for enhanced signal processing, while part number 781429-01 does not have this feature.
Feature | Specification |
---|---|
Part Number | 781429-01, 781429-02 |
Manufacturer | National Instruments |
Product | PXIe-5603 RF Signal Downconverter Module |
Versions | Without pre-amp, With pre-amp (781429-02) |
Function | Convert RF frequency to a lower level for digitization |
Max Center Frequency | Up to 3.6 GHz |
Connector Type | SMA female |
Coupling Supported | AC and DC |
Max DC Input Voltage | ±25 VDC |
Max IF Output Level | +22 dBm |
Resolution and Temperature Stability | Not less than NI PXIe 5622 |
Power Requirements | 1.7 A at +3.3 VDC, 1.8 A at +12 VDC |
LO IN Max Safe Voltage | 25 VDC |
LO OUT Max Safe Voltage | 0 VDC |
Weight | 32.0 oz |