Description
The National Instruments SCXI-1141 Lowpass Filter Input Module, part number 776572-41, falls under the SCXI & Legacy category. This module is specifically designed to cater to applications requiring lowpass elliptic filters and features differential-input amplifiers for enhanced signal integrity.
It supports 8 channels, allowing for multiple signal inputs, and boasts a high sampling rate of up to 333 kS/s. One of its remarkable features is the steep attenuation rate of 135 dB/octave, ensuring precise filtering of unwanted frequencies. The SCXI-1141 is compatible with National Instruments E/M Series DAQ instruments, making it a versatile choice for a wide range of data acquisition systems.
For optimal performance, it is recommended to use the SCXI-1304 or SCXI-1305 Shielded Terminal Blocks. These terminal blocks are designed to minimize noise and ensure stable connections. The module also offers 10,000 discrete software-programmable cut-off frequencies, providing flexibility in filtering applications. Additionally, the inclusion of an external clock input/output feature enhances its ability to synchronize with other devices.
An auto-zero mode is available to compensate for DC offset, ensuring accurate measurements over time. The module is supported by NI-DAQmx driver software, facilitating easy integration and configuration within your system. Lastly, its physical dimensions are 1.2 x 6.8 x 8 inches, making it compact and easy to fit into various setups.
| Specification | Detail |
|---|---|
| Part Number | 776572-41 |
| Category | SCXI & Legacy |
| Model | SCXI-1141 |
| Description | National Instruments SCXI-1141 Lowpass Filter Input Module |
| Filter Type | Lowpass elliptic filters |
| Input Type | Differential-input amplifiers |
| Channels | 8 |
| Sampling Rate | Up to 333 kS/s |
| Attenuation Rate | 135 dB/octave |
| Compatibility | National Instruments E/M Series DAQ instruments |
| Recommended Terminal Blocks | SCXI-1304, SCXI-1305 Shielded Terminal Blocks |
| Cut-off Frequencies | 10,000 discrete software-programmable |
| External Clock Input/Output | Yes |
| Auto-zero Mode | Available |
| Driver Software | NI-DAQmx |
| Physical Dimensions | 1.2 x 6.8 x 8
Question 1: What is the sampling rate of SCXI-1141? Question 2: How many channels does the SCXI-1141 support? Question 3: What type of filters does SCXI-1141 use? Question 4: What terminal blocks are recommended for SCXI-1141? Question 5: Is the SCXI-1141 compatible with E/M Series DAQ? |