img

182610F-02

The SCXI-1142 is an 8-channel, 8th-order Bessel filter, compatible with National Instruments E/M Series DAQ, featuring multiplexed and parallel modes.

In Stock | Ships Today

img

    Description

    The SCXI-1142, with part number 776572-42, falls under the category of SCXI & Legacy products. This model is an 8-Channel Bessel Filter, specifically designed to be used with National Instruments E/M Series DAQ systems. The filter type, as indicated, is Bessel, known for its smooth phase response and is ideal for applications requiring minimal phase distortion.

    It features 8 channels, which can operate in both multiplexed and parallel modes. This flexibility allows for efficient data acquisition and processing in various complex setups. The filter order is 8th-order, providing a higher degree of signal fidelity and accuracy.

    One of the key features of the SCXI-1142 is its calibration capabilities. It is equipped with hardware designed for error elimination, supporting automatic input zeroing and the use of an external reference voltage for calibration purposes. This ensures high precision and reliability in measurements. Additionally, the module includes DC compensation to further enhance its performance.

    For maintaining calibration constants, the SCXI-1142 is equipped with onboard EEPROM. This feature ensures that calibration data is preserved, facilitating easy and accurate recalibration when necessary. Despite being announced as obsolete by National Instruments, the SCXI-1142 remains available for purchase and repairs through Apex Waves, ensuring that users can continue to rely on its performance and capabilities.

    Specification Detail
    Part Number 776572-42
    Category SCXI & Legacy
    Model SCXI-1142
    Description 8-Channel Bessel Filter
    Filter Type Bessel
    Channels 8
    Compatibility National Instruments E/M Series DAQ
    Operation Modes Multiplexed and Parallel
    Filter Order 8th-order
    Calibration Hardware present for error elimination, supports automatic input zeroing and external reference voltage for calibration
    DC Compensation Yes
    EEPROM Onboard for calibration constants
    Obsolete Status Announced by National Instruments, available for purchase and repairs by Apex Waves

    Question 1: What is the filter type of SCXI-1142?
    Answer 1: It’s an 8th-order Bessel filter.

    Question 2: Can SCXI-1142 operate in parallel mode?
    Answer 2: Yes, it supports both multiplexed and parallel modes.

    Question 3: Does SCXI-1142 support automatic input zeroing?
    Answer 3: Yes, it has automatic input zeroing for calibration.

    Question 4: What is used for SCXI-1142’s calibration?
    Answer 4: It uses an external reference voltage for calibration.

    Question 5: Is EEPROM included in SCXI-1142 for any purpose?
    Answer 5: Yes, it has onboard EEPROM for maintaining calibration constants.