The product with the part number 776572-60 falls under the category of PXI Switches and is designated as model SCXI-1160. This model is described as a MODULE ASSY, SCXI-1160, 16 CHANNEL SPDT RELAY, which means it is an assembly module designed with 16 channels of Single Pole Double Throw (SPDT) relay. The relay type utilized in this module is specified as SPDT Form C, Electromechanical, Latching Relays, which are known for their reliable switching capabilities.
This PXI Switch has a number of channels totaling 16, allowing for significant flexibility in connecting multiple circuits. It supports a maximum switching rate of 50 operations per second, ensuring swift response times for applications that require rapid switching. The switching capacity of the module is robust, being able to handle 2 A at 250 VRMS or 2 A at 30 VDC, making it suitable for a wide range of electrical loads.
The relay operating time is impressively quick at 10 ms, ensuring minimal delay in switching operations. With an offset voltage of 3 μV, the module ensures high precision in signal processing. Compatibility is a strong suit of this module, supporting various software including NI-SWITCH, LabVIEW, and LabWindows/CVI, enhancing its versatility in different programming environments. Moreover, it is compatible with a range of boards including NI MIO-16 Boards; Lab-NB, Lab-PC, Lab-PC+, Lab-LC, and PC-LPM-16 boards; DIO-24, DIO-32F, DIO-96 boards, making it a highly adaptable solution for various hardware setups.
The module is equipped with five jumpers (W1, W2, W3, W4, W5), providing additional flexibility in configuration. Its dimensions are 1.2 x 6.8 x 8.0 in, making it compact enough for
| Specification | Detail |
|---|---|
| Part Number | 776572-60 |
| Category | PXI Switches |
| Model | SCXI-1160 |
| Description | MODULE ASSY,SCXI-1160,16 CHANNEL SPDT RELAY |
| Relay Type | SPDT Form C, Electromechanical, Latching Relays |
| Number of Channels | 16 |
| Maximum Switching Rate | 50 operations per second |
| Switching Capacity | 2 A at 250 VRMS or 2 A at 30 VDC |
| Relay Operating Time | 10 ms |
| Offset Voltage | 3 μV |
| Software Compatibility | NI-SWITCH, LabVIEW, LabWindows/CVI |
| Board Compatibility | NI MIO-16 Boards; Lab-NB, Lab-PC, Lab-PC+, Lab-LC, and PC-LPM-16 boards; DIO-24, DIO-32F, DIO-96 boards |
| Jumpers | Five (W1, W2, W3, W4, W5) |
| Dimensions | 1.2 x 6.8 x 8.0 in |
| Obsolete Status | Announced by National Instruments |
Question 1: What is the part number for the SCXI-1160?
Answer 1: 776572-60
Question 2: How many channels does the SCXI-1160 have?
Answer 2: 16 channels
Question 3: What is the max switching rate for the SCXI-1160?
Answer 3: 50 ops/sec
Question 4: What type of relays does SCXI-1160 use?
Answer 4: SPDT Form C, Electromechanical, Latching Relays
Question 5: Is the SCXI-1160 compatible with LabVIEW?
Answer 5: Yes