Description
The SCXI-1314 Front-Mounting Terminal Block with part number 777687-14 falls under the category of SCXI & Legacy. This particular model, SCXI-1314, is designed to provide a reliable and efficient connection solution for various applications.
It is specifically compatible with the SCXI-1520 module, ensuring seamless integration for users. The terminal block features 88 screw terminals, which are configured in eight groups of 11, offering ample connection points for various configurations.
Additionally, it includes two precision 100 kΩ shunt calibration resistors and one precision 350 Ω quarter-bridge completion resistor (default), which is user replaceable. This allows for accurate measurements and adaptability to specific user needs.
Software compatibility is a key feature of the SCXI-1314, supporting a range of software including NIDAQmx, LabVIEW, LabWindows/CVI, and Measurement Studio. This compatibility ensures that users can integrate the terminal block into their existing setups without the need for extensive modifications.
Operating within a temperature range of 0 to 50 °C and a storage temperature range of –20 to 70 °C, the SCXI-1314 is built to withstand various environmental conditions. Additionally, its relative humidity tolerance of 10 to 90% (non-condensing) further attests to its robustness in different working environments.
Compliance with safety standards such as IEC 61010-1, EN 61010-1, UL 61010-1, and CAN/CSA C22.2 No. 61010-1 underscores its reliability and safety for use in a wide range of applications. Although its obsolete status has been announced, the SCXI-1314 remains a valuable tool for users requiring a dependable front-mounting terminal block solution.
| Specification | Detail |
|---|---|
| Part Number | 777687-14 |
| Category | SCXI & Legacy |
| Model | SCXI-1314 |
| Description | SCXI-1314 Front-Mounting Terminal Block (Screw Terminals) |
| Compatible Module | SCXI-1520 |
| Screw Terminals | 88, configured in eight groups of 11 |
| Shunt Calibration Resistors | Two precision 100 kΩ |
| Quarter-Bridge Completion Resistor | One precision 350 Ω (default), user replaceable |
| Software Compatibility | NIDAQmx, LabVIEW, LabWindows/CVI, Measurement Studio |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | –20 to 70 °C |
| Relative Humidity | 10 to 90% (non-condensing) |
| Safety Standards | IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA C22.2 No. 61010-1 |
| Obsolete Status | Announced by
Question 1: What is the part number for the SCXI-1314? Question 2: How many screw terminals does the SCXI-1314 have? Question 3: Is the SCXI-1314 compatible with the SCXI-1520? Question 4: What software supports the SCXI-1314? Question 5: What is the operating temperature range of the SCXI-1314? |