Description
The Part Number 777687-15 refers to a specific product within the SCXI & Legacy category, known as the SCXI-1315. This product is a Front Mounting Terminal Block designed specifically for use with the SCXI-1540 LVDT Module. It features 8 channels, providing a comprehensive solution for various measurement and testing setups.
Each channel on the SCXI-1315 is organized into 8 groups, with 6 terminals per channel, totaling 48 terminals. This organization allows for versatile and efficient connection setups. The terminal block is compatible with Linear Variable Differential Transformers (LVDTs), Rotary Variable Differential Transformers (RVDTs), and Resolvers, making it a highly adaptable component for a wide range of applications.
When it comes to connectivity, the SCXI-1315 accommodates a Field Wire Gauge range from 26 to 14 AWG, ensuring compatibility with various wire sizes for secure and reliable connections. The terminal block operates within a temperature range of 0 to 50 °C and can be stored in temperatures ranging from -20 to 70 °C. It is designed to function effectively in environments with a Relative Humidity of 10 to 90% (Non-condensing).
The SCXI-1315 is software compatible with several National Instruments software solutions, including NIDAQ 7, LabVIEW, LabWindows/CVI, Measurement Studio, and VI Logger. This compatibility ensures seamless integration and functionality within a variety of development and testing environments.
Despite its Obsolete Status, as announced by National Instruments, the SCXI-1315 remains available for purchase and repairs through Apex Waves. This ensures that users of this specific terminal block can continue to receive support and replacements if necessary, maintaining their existing setups without the need for extensive overhauls or replacements.
| Specification | Detail |
|---|---|
| Part Number | 777687-15 |
| Category | SCXI & Legacy |
| Model | SCXI-1315 |
| Description | Front Mounting Terminal Block for SCXI-1540 LVDT Module |
| Channels | 8 |
| Terminal Count | 48 |
| Terminal Organization | 8 groups of 6 terminals per channel |
| Compatible With | Linear Variable Differential Transformers (LVDTs), Rotary Variable Differential Transformers (RVDTs), Resolvers |
| Field Wire Gauge | 26 to 14 AWG |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity | 10 to 90% (Non-condensing) |
| Software Compatibility | NIDAQ 7, LabVIEW, LabWindows/CVI, Measurement Studio, VI Logger |
| Obsolete Status | Announced by National Instruments, available for purchase and repairs by Apex Waves |
Question 1: What is the part number for SCXI-1315?
Answer 1: 777687-15
Question 2: How many channels does SCXI-1315 have?
Answer 2: 8 channels
Question 3: What is the compatible wire gauge for SCXI-1315?
Answer 3: 26 to 14 AWG
Question 4: Can SCXI-1315 work with LVDTs?
Answer 4: Yes, compatible with LVDTs.
Question 5: Is the SCXI-1315 software compatible with LabVIEW?
Answer 5: Yes, compatible with LabVIEW.