Description
The National Instruments SCXI-1349 Shielded Cable Adapter, part number 182671-01, falls under the SCXI & Legacy category. This model, SCXI-1349, is designed to offer an efficient solution for system connectivity and signal integrity. It serves as a critical component in setups involving 68-pin E Series DAQ Devices (with the exception of 61XXE models) and SCXI modules, excluding switch modules. Compatibility extends to a comprehensive array of devices and systems, ensuring a broad application spectrum.
Connectivity options are robust, featuring a 68-pin male connector on the front panel, alongside a 50-pin male connector on the PCB, and a 50-pin female connector on the back. This adapter facilitates seamless integration within setups requiring high-density connections. For operation, several items are required, including a computer, a compatible 68-pin E Series DAQ Device, an SCXI-1000/1001/1000DC Chassis, one or more SCXI modules, a small flathead screwdriver for installation, an installation guide, and the NI SCXI-1349 shielded cable assembly.
When it comes to cable compatibility, the adapter supports a range of lengths and types, including 1 m or 2 m SH68-68-EP, 0.5 m or 1 m SHC68-68-EP, and 1 m PSHR68-68 cables. This flexibility in cable selection allows for customized setup configurations to meet specific connectivity needs. The maximum working voltage capability of the adapter is 30 Vrms, 42 Vpk, and 60 VDC, indicating its suitability for various electrical environments.
For optimal performance, it is recommended to operate the device within a temperature range of 0 to 50 °C. It can withstand a storage temperature range between -20 to 70 °C, ensuring durability and reliability across different climatic conditions. The relative humidity range is set between 10 to 90% (noncondensing), providing assurance
| Specification | Detail |
|---|---|
| Part Number | 182671-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1349 |
| Description | National Instruments SCXI-1349 Shielded Cable Adapter |
| Compatibility | 68-pin E Series DAQ Devices (except 61XXE models), SCXI modules (except switch modules) |
| Connectors | 68-pin male (front panel), 50-pin male (PCB), 50-pin female (back) |
| Required Items | Computer, 68-pin E Series DAQ Device, SCXI-1000/1001/1000DC Chassis, SCXI module(s), Small flathead screwdriver, Installation guide, NI SCXI-1349 shielded cable assembly |
| Compatible Cables | 1 m or 2 m SH68-68-EP, 0.5 m or 1 m SHC68-68-EP, 1 m PSHR68-68 |
| Maximum Working Voltage | 30 Vrms, 42 Vpk, 60 VDC |
| Recommended Operating Temperature | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Range | 10 to 90% (noncondensing) | Question 1: What is the part number for the SCXI-1349?