Description
The SCXI-1328 is identified by its part number 185137C-01L (777687-28) and falls under the SCXI & Legacy category. This model is a High-Accuracy Isothermal Terminal Block designed for superior performance and compatibility.
It is compatible with several modules, including the SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, and SCXI-1126, ensuring a wide range of applications. The terminal block features 18 screw terminals, including a pair dedicated to chassis ground, accommodating a maximum field wire gauge of 26 to 14 AWG. It operates with DC coupling, ensuring stable connections.
The accuracy of the SCXI-1328 is remarkable, offering 0.5 °C accuracy at temperatures ranging from 15 to 35 °C and 0.9 °C accuracy at temperatures from 0 to 15 °C & 35 to 55 °C. This high precision is achieved through its advanced features, including a precision thermistor, an aluminum isothermal plate, and an onboard temperature sensor for cold-junction compensation.
Software support for the SCXI-1328 includes LabVIEW (Convert Thermistor VI) and NI-DAQ (Thermistor convert function call), facilitating easy integration into existing systems. Performance verification of the device is conducted using industry-standard equipment such as the Fluke 5700A, NI 4060, and HP 34401A.
The terminal block can safely operate at a maximum working voltage of 300 Vrms, applicable both channel-to-ground and channel-to-channel, ensuring safety and reliability in a variety of settings.
| Specification | Detail |
|---|---|
| Part Number | 185137C-01L (777687-28) |
| Category | SCXI & Legacy |
| Model | SCXI-1328 |
| Description | High-Accuracy Isothermal Terminal Block |
| Compatibility | SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 modules |
| Screw Terminals | 18 (1 pair for chassis ground) |
| Maximum Field Wire Gauge | 26 to 14 AWG |
| Coupling | DC |
| Accuracy | 0.5 °C at 15 to 35 °C, 0.9 °C at 0 to 15 °C & 35 to 55 °C |
| Features | Precision thermistor, aluminum isothermal plate, onboard temperature sensor for cold-junction compensation |
| Software Support | LabVIEW (Convert Thermistor VI), NI-DAQ (Thermistor convert function call) |
| Performance Verification | Fluke 5700A, NI 4060, HP 34401A |
| Maximum Working Voltage | 300 Vrms (channel-to-ground and channel-to-channel
Question 1: What’s the part number for SCXI-1328? Question 2: How accurate is the SCXI-1328 at 15-35 °C? Question 3: What’s the max wire gauge the SCXI-1328 supports? Question 4: Can the SCXI-1328 operate at 300 Vrms? Question 5: Is SCXI-1328 compatible with LabVIEW? |