Description
The SCXI-1520, identifiable by its part numbers 777966-20, 186338-01, falls under the SCXI & Legacy category. This model is compatible with a range of accessories including the SCXI-1314 Screw Terminal Block, SCXI-1310 Connector and Shell Assembly, TBX-96 DIN-rail mounted Terminal Block, and the SCXI-1314T RJ-50 Terminal Block. It is equipped with 8 analog input channels and boasts a variety of features designed to enhance its performance.
Among its noteworthy features are the automatic calibration, a programmable amplifier, a programmable 4-pole Butterworth filter, and a 0 to 10 V programmable excitation source with remote sense for each channel. Additionally, it has a simultaneous-sample-and-hold feature which is crucial for accurate data acquisition. The SCXI-1520 supports various operation modes including a parallel mode for high-speed acquisitions and random scanning capability, making it versatile for a range of applications.
Its software compatibility includes NI-DAQmx driver software, LabVIEW, LabWindows/CVI, and Measurement Studio, ensuring ease of integration into existing systems. Weighing in at 10.4 oz. and with dimensions of 1.2 x 6.9 x 8.0 in., this module is compact and easy to accommodate in space-constrained setups. It operates within a temperature range of 0 to 50 °C, offering reliability in varied environmental conditions.
Although its obsolete status has been announced by National Instruments, it remains available for purchase and repairs through Apex Waves. Furthermore, calibration services are available for this model, ensuring it maintains its accuracy and reliability over time.
| Specification | Details |
|---|---|
| Part Number | 777966-20, 186338-01 |
| Category | SCXI & Legacy |
| Model | SCXI-1520 |
| Compatible Accessories | SCXI-1314 Screw Terminal Block, SCXI-1310 Connector and Shell Assembly, TBX-96 DIN-rail mounted Terminal Block, SCXI-1314T RJ-50 Terminal Block |
| Input Channels | 8 analog input channels |
| Features | Automatic calibration, Programmable amplifier, Programmable 4-pole Butterworth filter, 0 to 10 V programmable excitation source with remote sense for each channel, Simultaneous-sample-and-hold feature |
| Software Compatibility | NI-DAQmx driver software, LabVIEW, LabWindows/CVI, Measurement Studio |
| Operation Modes | Parallel mode for high-speed acquisitions, Random scanning capability |
| Weight | 10.4 oz. |
| Dimensions | 1.2 x 6.9 x 8.0 in. |
| Operating Temperature Range | 0 to 50 °C |
| Obsolete Status | Announced by National Instruments; available for purchase and repairs by Apex Waves |
| Calibration | Available
Question 1: What is the weight of SCXI-1520? Question 2: Can SCXI-1520 use automatic calibration? Question 3: Does SCXI-1520 support LabVIEW integration? Question 4: What is the operating temperature range of SCXI-1520? Question 5: Is the SCXI-1520 obsolete? |