Description
The National Instruments SCXI-1191 Multiplexer Module is a high-performance device with a single-pole double-throw (SPDT) switch configuration, capable of handling bandwidths from DC to 4 GHz. It has a maximum rated switch voltage of 30 V and can sustain a maximum rated current of 0.33 A at 30 V. Designed for multiplexed operation only, this module is compatible with the PXI-1010 and PXI-1011 chassis.
Integration with a DAQ system is streamlined as the module features a local bus interface for a PXI multifunction I/O module located in the farthest right slot, eliminating the need for external cabling. Despite its obsolete status, which has been formally announced by National Instruments, the SCXI-1191 remains accessible for purchase and can be serviced by Apex Waves.
Specification | Detail |
---|---|
Product Name | National Instruments SCXI-1191 Multiplexer Module |
Switch Configuration | Single-pole double-throw (SPDT) |
Bandwidth | DC to 4 GHz |
Maximum Rated Switch Voltage | 30 V |
Maximum Rated Current | 0.33 A at 30 V |
Mode of Operation | Multiplexed only |
Compatible Chassis | PXI-1010, PXI-1011 |
Local Bus Interface | Available for PXI multifunction I/O module in the farthest right slot |
External Cabling Requirement | None (internal connection to PXI bus) |
Obsolete Status | Announced by National Instruments |
Availability | Available for purchase and repairs by Apex Waves |
Question 1: What are the specifications and compatibility details of the discontinued National Instruments SCXI-1191 Multiplexer Module, and how does it integrate with a DAQ system?
Answer 1: The National Instruments SCXI-1191 Multiplexer Module is compatible with the PXI-1010 and PXI-1011 chassis.
Question 2: What are the specifications and compatibility features of the National Instruments SCXI-1191 Multiplexer Module, and how does its design facilitate integration with a DAQ system despite its obsolete status?
Answer 2: The National Instruments SCXI-1191 Multiplexer Module is a high-performance device with an SPDT switch configuration, capable of handling bandwidths up to 4 GHz, with a maximum switch voltage of 30 V and a current capacity of 0.33 A at that voltage. It is designed exclusively for multiplexed operation and is compatible with PXI-1010 and PXI-1011 chassis. Integration with a DAQ system is simplified through a local bus interface which connects to a
Question 3: What is the maximum rated current that the National Instruments SCXI-1191 Multiplexer Module can sustain at its maximum rated voltage of 30 V?
Answer 3: The discontinued National Instruments SCXI-1191 Multiplexer Module is a high-performance SPDT switch with a bandwidth from DC to 4 GHz, a maximum switch voltage of 30 V, and a maximum current of 0.33 A at 30 V, designed exclusively for multiplexed operations and compatible with PXI-1010 and PXI-1011 chassis; it integrates seamlessly with a DAQ system via a local bus interface for a PXI multifunction I/O module, neg
Question 4: What are the voltage and current specifications of the National Instruments SCXI-1191 Multiplexer Module, and which chassis is it compatible with?
Answer 4: The National Instruments SCXI-1191 Multiplexer Module has a maximum rated switch voltage of 30 V and can handle a maximum rated current of 0.33 A at 30 V; it is compatible with the PXI-1010 and PXI-1011 chassis.
Question 5: What are the specific chassis with which the National Instruments SCXI-1191 Multiplexer Module is compatible?
Answer 5: The National Instruments SCXI-1191 Multiplexer Module can sustain a maximum rated current of 0.33 A at its maximum rated voltage of 30 V.