Description
The National Instruments SCXI-1324 Shielded Terminal Block, with Part Number 777687-24, is specifically designed for compatibility with the SCXI-1160 Relay Module. This robust terminal block features 48 screw terminals and is engineered without a cold-junction sensor to focus on high-voltage applications. It offers 250 VRMS common-mode isolation for both channel-to-channel and channel-to-ground scenarios, supporting a maximum signal current of 2 A per channel.
Users can connect wires ranging from 26 to 16 AWG to this terminal block, which is built to operate within a temperature range of 0 to 50 °C and can be stored at temperatures ranging from –20 to 70 °C. The device is also designed to withstand a relative humidity range of 5 to 90% without condensation. The SCXI-1324 adheres to stringent electrical safety standards, including IEC 61010-1, UL 3111-1, and CAN/CSA C22.2 No. 1010.1, ensuring a reliable and safe operation.
For technical assistance and support, users can access National Instruments’ dedicated support page at www.ni.com/support.
Specification | Detail |
---|---|
Part Number | 777687-24 |
Compatible Module | SCXI-1160 Relay Module |
Type | Shielded Terminal Block |
Screw Terminals | 48 |
Cold-Junction Sensor | Not included |
Common-Mode Isolation | 250 VRMS (channel to channel and channel to ground) |
Maximum Signal Current | 2 A per channel |
Maximum Field Wire Gauge | 26 to 16 AWG |
Operating Temperature Range | 0 to 50 °C |
Storage Temperature Range | –20 to 70 °C |
Relative Humidity Range | 5 to 90% (non-condensing) |
Electrical Safety Standards | IEC 61010-1, UL 3111-1, CAN/CSA C22.2 No. 1010.1 |
Technical Support | www.ni.com/support |
Question 1: What type of wire gauge is suitable for connecting to the SCXI-1324 Shielded Terminal Block and within what temperature range is the device designed to operate?
Answer 1: Wires ranging from 26 to 16 AWG are suitable for connecting to the SCXI-1324 Shielded Terminal Block, and the device is designed to operate within a temperature range of 0 to 50 °C.
Question 2: What are the specifications and safety standards associated with the National Instruments SCXI-1324 Shielded Terminal Block, and where can users find technical support for this device?
Answer 2: The National Instruments SCXI-1324 Shielded Terminal Block supports a maximum signal current of 2 A per channel and adheres to the safety standards IEC 61010-1, UL 3111-1, and CAN/CSA C22.2 No. 1010.1.
Question 3: What is the maximum signal current per channel supported by the National Instruments SCXI-1324 Shielded Terminal Block, and what are the safety standards it adheres to?
Answer 3: The National Instruments SCXI-1324 Shielded Terminal Block, with Part Number 777687-24, is designed for the SCXI-1160 Relay Module and features 48 screw terminals, 250 VRMS common-mode isolation, a maximum signal current of 2 A per channel, compatibility with 26 to 16 AWG wires, an operational temperature range of 0 to 50 °C, storage temperatures from –20 to 70 °C, and can withstand 5 to
Question 4: What are the key specifications and compatibility details of the National Instruments SCXI-1324 Shielded Terminal Block, and where can users find technical support for this device?
Answer 4: The National Instruments SCXI-1324 Shielded Terminal Block, with Part Number 777687-24, is designed for use with the SCXI-1160 Relay Module and features 48 screw terminals, 250 VRMS common-mode isolation, and can handle up to 2 A per channel without a cold-junction sensor, catering to high-voltage applications. It accepts 26 to 16 AWG wires, operates between 0 to 50 °C, can be stored from –
Question 5: What are the key specifications and safety standards associated with the National Instruments SCXI-1324 Shielded Terminal Block, and where can users seek technical support for this product?
Answer 5: The National Instruments SCXI-1324 Shielded Terminal Block, with Part Number 777687-24, is designed for high-voltage applications and features 48 screw terminals, 250 VRMS common-mode isolation, and supports up to 2 A per channel without a cold-junction sensor. It can accommodate wires from 26 to 16 AWG, operates within a temperature range of 0 to 50 °C, and can be stored at temperatures between –20 to 70 °