Description
The product with part numbers 142840B-01L and 142840-02L falls under the SC Express category and is identified as model TB-4310. This model is specifically a NI TB-4310 Terminal Block designed for compatibility with the PXIe-4310 module. It is categorized under measurement category O.
The maximum safe voltage limits for this terminal block are up to 600 VDC (AI+ to AI-), with an input voltage range of ±11 V (AI+ to AI-). In terms of isolation, it offers a channel to channel isolation voltage of either 600 VDC/Vpk or 300 Vrms, ensuring safe operation and protection against electrical interference. Furthermore, it is rated for a transient overvoltage of up to 2,500 Vpk, highlighting its robustness in handling voltage spikes.
It is important to note that the TB-4310 is not designed to be powered from external sources or main utility outlets. This specification underscores the device’s intended use and safety considerations in its operational environment.
| Specification | Detail |
|---|---|
| Part Number | 142840B-01L, 142840-02L |
| Category | SC Express |
| Model | TB-4310 |
| Description | NI TB-4310 Terminal Block |
| Compatibility | PXIe-4310 |
| Measurement Category | O |
| Maximum Safe Voltage Limits | 600 VDC (AI+ to AI-) |
| Input Voltage | ±11 V (AI+ to AI-) |
| Channel to Channel Isolation Voltage | 600 VDC/Vpk or 300 Vrms |
| Rated Transient Overvoltage | 2,500 Vpk |
| Power Source | Not designed to be powered from external sources or main utility outlets |
Question 1: What is the max voltage limit for TB-4310?
Answer 1: 600 VDC (AI+ to AI-)
Question 2: Can TB-4310 be powered externally?
Answer 2: No, it’s not designed for external power.
Question 3: What is the input voltage range of TB-4310?
Answer 3: ±11 V (AI+ to AI-)
Question 4: What’s TB-4310’s transient overvoltage rating?
Answer 4: 2,500 Vpk
Question 5: Is TB-4310 compatible with PXIe-4310 module?
Answer 5: Yes, it’s designed for PXIe-4310 compatibility.