The National Instruments TBX-1326 High-Voltage Terminal Block, part number 777207-26, features 48 screw terminals configured in 8 isolated groups, compatible with several SCXI modules, and supports various connection configurations for different uses.

In Stock | Ships Today

img

    Description

    The National Instruments TBX-1326 High-Voltage Terminal Block, with Part Number 777207-26, features 48 screw terminals organized into 8 groups, each group comprising 6 terminals including 1 ground (GND), 1 positive supply voltage (Vcc), and 4 signal channels.

    This terminal block is designed for compatibility with several modules, including the SCXI-1163, SCXI-1162HV, SCXI-1162, and SCXI-1163R. It connects through an SH48-48-B cable and supports convenient signal wiring with labeled rows A, B, and C.

    For mounting, it is fully compatible with DIN EN 50 022 and DIN EN 50 035 DIN rails. The terminal block’s versatility allows it to serve various functions depending on the module it’s paired with; for instance, with the SCXI-1162, the Vcc terminal is used for power or reference voltage, the CH(X) terminals for digital input signals, and the GND terminal remains unused.

    When used with the SCXI-1162HV, the GND terminal provides a ground reference and the CH(X) terminals are used for the input signal, leaving the Vcc terminal unused. The SCXI-1163 module utilizes all terminals, with Vcc for power supply, GND for ground, and CH(X) for digital output signals. Lastly, in combination with the SCXI-1163R, the Vcc terminal is again unused, GND serves as a common pole, and CH(X) is used for relay inputs.

    Feature Description
    Part Number 777207-26
    Product Name National Instruments TBX-1326 High-Voltage Terminal Block
    Terminal Count 48 screw terminals
    Terminal Configuration 8 groups, each with 6 terminals (1 GND, 1 Vcc, 4 channels)
    Compatible Modules SCXI-1163, SCXI-1162HV, SCXI-1162, SCXI-1163R
    Connection Cable SH48-48-B cable
    Signal Labeling Labeled rows A, B, and C
    Compatible DIN Rails DIN EN 50 022, DIN EN 50 035
    Use with SCXI-1162 Vcc for power/reference voltage, CH(X) for digital input signals, GND unused
    Use with SCXI-1162HV Vcc unused, GND for ground reference, CH(X) for input signal
    Use with SCXI-1163 Vcc for power supply, GND for ground, CH(X) for digital output signal
    Use with SCXI-1163R Vcc unused, GND as a common pole, CH(X) for relay inputs

    Question 1: How does the configuration of the National Instruments TBX-1326 High-Voltage Terminal Block differ when used with the SCXI-1162HV module compared to when it is paired with the SCXI-1163 module?
    Answer 1: When the National Instruments TBX-1326 High-Voltage Terminal Block is used with the SCXI-1162HV module, the GND terminal provides a ground reference and the CH(X) terminals are used for the input signal, with the Vcc terminal left unused, whereas with the SCXI-1163 module, all terminals are utilized, with Vcc for power supply, GND for ground, and CH(X) for digital output signals.

    Question 2: How is the National Instruments TBX-1326 High-Voltage Terminal Block utilized differently when paired with the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules?
    Answer 2: When paired with the SCXI-1162 module, the National Instruments TBX-1326 High-Voltage Terminal Block uses the Vcc terminal for power or reference voltage, the CH(X) terminals for digital input signals, and leaves the GND terminal unused; with the SCXI-1162HV, the GND terminal provides a ground reference, the CH(X) terminals are for the input signal, and the Vcc terminal remains unused; for the SCXI-1163 module, all

    Question 3: What are the different ways in which the Vcc, GND, and CH(X) terminals of the National Instruments TBX-1326 High-Voltage Terminal Block are utilized when paired with various SCXI modules such as the SCXI-1163, SCXI-1162HV, SCXI-1162, and the SCXI-1163R?
    Answer 3: When used with the SCXI-1162 module, the National Instruments TBX-1326 High-Voltage Terminal Block’s Vcc terminal is utilized for power or reference voltage, the CH(X) terminals for digital input signals, and the GND terminal remains unused, whereas with the SCXI-1163 module, all terminals are utilized with Vcc for power supply, GND for ground, and CH(X) for digital output signals.

    Question 4: What are the specific functions of the Vcc, GND, and CH(X) terminals on the National Instruments TBX-1326 High-Voltage Terminal Block when paired with various SCXI modules such as SCXI-1163, SCXI-1162HV, SCXI-1162, and SCXI-1163R?
    Answer 4: When the National Instruments TBX-1326 High-Voltage Terminal Block is paired with the SCXI-1163 module, the Vcc terminal is used for power supply, the GND terminal for ground, and the CH(X) terminals for digital output signals; with the SCXI-1162HV, the GND terminal provides a ground reference, CH(X) terminals are for the input signal, and the Vcc terminal remains unused; for the SCXI-1162, the Vcc

    Question 5: How does the National Instruments TBX-1326 High-Voltage Terminal Block’s functionality differ when used with the SCXI-1162 module compared to its use with the SCXI-1163 module?
    Answer 5: When paired with different SCXI modules, the National Instruments TBX-1326 High-Voltage Terminal Block utilizes the Vcc, GND, and CH(X) terminals in the following ways: with the SCXI-1162, Vcc is for power or reference voltage, CH(X) is for digital input signals, and GND is unused; with the SCXI-1162HV, GND provides a ground reference, CH(X) is used for the input signal, and Vcc