img

779974-02

The USB-6225 is a PC-based multifunction DAQ with 80 analog input channels, 16-bit resolution, and a max sample rate of 250 kS/s.

In Stock | Ships Today

img

    Description

    The USB-6225 is a PC-based Multifunction Data Acquisition (DAQ) device with part numbers including 779974-01, 779973-02, 779973-04, 779973-01, and 779974-04. This device offers a wide range of features for various data acquisition needs.

    It boasts an impressive 80 analog input channels, which can be configured as either 40 differential channels or 80 single-ended channels. This flexibility allows for a broad array of signal measurements. The 16-bit Analog-to-Digital Converter (ADC) resolution ensures high precision in readings.

    For sampling rates, the USB-6225 can achieve a maximum sample rate of 250 kS/s for both single and multiple channel configurations, making it suitable for capturing fast-changing signals. The timing accuracy is maintained at 50 ppm of the sample rate, ensuring precise timing for measurements.

    The device requires a recommended warm-up time of 30 minutes and should undergo calibration at least once a year to maintain accuracy. It supports various input ranges, including ±0.2V, ±1V, ±5V, and ±10V, with a maximum working voltage of ±11V for analog inputs.

    The Input FIFO size is 4,095 samples, providing a buffer for data before processing. Additionally, the device features overvoltage protection for all analog input and sense channels, with an input current limit of ±20 mA maximum under overvoltage conditions, ensuring the safety of the device and connected sensors.

    On the output side, the USB-6225 includes 2 analog output channels with a 16-bit DAC resolution. The maximum update rate is 833 kS/s for one channel and 740 kS/s for both channels, allowing for precise control signals to be generated.

    Specification Detail
    Part Numbers 779974-01, 779973-02, 779973-04, 779973-01, 779974-04
    Category PC-based Multifunction DAQ
    Model USB-6225
    Analog Input Channels 80 (40 differential channels or 80 single-ended channels)
    ADC Resolution 16-bit
    Maximum Sample Rate (Single Channel) 250 kS/s
    Maximum Sample Rate (Multiple Channels) 250 kS/s
    Timing Accuracy 50 ppm of sample rate
    Recommended Warm-Up Time 30 minutes
    Calibration Period At least once a year
    Input Ranges ±0.2V, ±1V, ±5V, ±10V
    Maximum Working Voltage (Analog Inputs) ±11V
    Input FIFO Size 4,095 samples
    Overvoltage Protection Yes, for all analog input and sense channels
    Input Current (Overvoltage Condition) ±20 mA maximum
    Analog Output Channels 2
    DAC Resolution 16 bit
    Maximum Update Rate (One Channel) 833 kS/s
    Maximum Update Rate (Both Channels) 740 kS/s
    Output

    Question 1: How many analog input channels does the USB-6225 have?
    Answer 1: 80 channels, configurable as 40 differential or 80 single-ended.

    Question 2: What is the max sample rate of the USB-6225?
    Answer 2: 250 kS/s for both single and multiple channel configurations.

    Question 3: What is the recommended warm-up time for the USB-6225?
    Answer 3: 30 minutes

    Question 4: What are the input voltage ranges supported by the USB-6225?
    Answer 4: ±0.2V, ±1V, ±5V, and ±10V

    Question 5: What is the maximum update rate for one analog output channel on the USB-6225?
    Answer 5: 833 kS/s