    The USB-6255 is a PC-based Multifunction DAQ device that boasts a range of part numbers including 779959-01, 779958-01, 779958-04, and 779959-04. This model falls under the category of PC-based Multifunction DAQ, designed to cater to various data acquisition needs.

    Described as the USB-6255 M Series DAQ (80 1.25MS/s AI, 24 Digital I/O, 2 AO) Mass Term, Japan (100 V), this device is engineered for high performance and reliability. It offers a 16-bit resolution, ensuring accurate data representation.

    With a minimum of 24 Digital I/O Lines, this device is versatile and capable of handling a variety of digital inputs and outputs. It also features 7 programmable input ranges, providing flexibility for different signal levels.

    The USB-6255 is equipped with 40 differential or 80 single-ended Analog Input Channels, making it highly adaptable for various sensor types and configurations. It supports an aggregate multichannel sampling rate of 750 kS/s, and an impressive single-channel sampling rate of 1.25 MS/s, ideal for capturing fast-changing signals.

    Its input impedance is rated at 820Ω, optimized for a wide range of sensor types. Furthermore, the device features multiple analog triggers, including a Start Trigger, Reference Trigger, and Pause Trigger, enhancing its capability to capture critical data points.

    The USB-6255 supports advanced triggering modes such as Analog edge triggering and Analog Window Triggering, providing users with the flexibility to initiate data acquisition based on specific signal conditions.

    Lastly, it is recommended that the USB-6255 undergoes calibration every 2 years to maintain its accuracy and reliability, ensuring it continues to meet the rigorous demands of various data acquisition applications.

    Specification Detail
    Part Numbers 779959-01, 779958-01, 779958-04, 779959-04
    Category PC-based Multifunction DAQ
    Model USB-6255
    Description USB-6255 M Series DAQ (80 1.25MS/s AI, 24 Digital I/O, 2 AO) Mass Term, Japan (100 V)
    Resolution 16-bit
    Digital I/O Lines Minimum of 24
    Programmable Input Ranges 7
    Analog Input Channels 40 differential or 80 single-ended
    Aggregate Multichannel Sampling Rate 750 kS/s
    Single-Channel Sampling Rate 1.25 MS/s
    Input Impedance 820Ω
    Analog Triggers Start Trigger, Reference Trigger, Pause Trigger
    Triggering Modes Analog edge triggering, Analog Window Triggering
    Recommended Calibration Interval 2 years

    Question 1: What is the bit resolution of the USB-6255?
    Answer 1: 16-bit

    Question 2: How many single-ended channels does the USB-6255 have?
    Answer 2: 80 channels

    Question 3: What is the max single-channel rate of the USB-6255?
    Answer 3: 1.25 MS/s

    Question 4: What types of triggering modes does USB-6255 support?
    Answer 4: Analog edge and window triggering

    Question 5: How often should the USB-6255 be calibrated?
    Answer 5: Every 2 years